首页 | 官方网站   微博 | 高级检索  
     


Development of nuclear radiation detectors based on epitaxially grown thick CdTe layers on n+-GaAs substrates
Authors:M. Niraula  K. Yasuda  K. Takagi  H. Kusama  M. Tominaga  Y. Yamamoto  Y. Agata  K. Suzuki
Affiliation:(1) Graduate School of Engineering, Nagoya Institute of Technology, Gokiso, Showa, 466-8555 Nagoya, Japan;(2) Department of Electrical Engineering, Hokkaido Institute of Technology, Maeda 7-15, Teine, 006-8585 Sapporo, Japan
Abstract:A CdTe/n+-GaAs heterojunction diode for a room-temperature nuclear radiation detector has been developed and demonstrated. The heterojunction diode was fabricated by growing a 2–5-μm-thick iodine-doped n-CdTe buffer layer on the n+-GaAs substrates, followed by about 100-μm-thick undoped p-like single crystalline CdTe layer using metalorganic vapor-phase epitaxy. The n-type buffer layer was found to be essential to improve the junction property of the diode detector. The diode detectors exhibited good rectification property and had the reverse leakage currents typically from 1 μA/cm2 to 5 μA/cm2 at 40 V bias. The detector clearly demonstrated its energy resolution capability by resolving the 59.54-keV gamma peak from the 241Am radioisotope during the radiation detection test.
Keywords:CdTe  epitaxial layer  heterojunction diode  radiation detector  spectroscopic detectors
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23