首页 | 官方网站   微博 | 高级检索  
     

受潮大型变压器异常试验结果浅析
引用本文:蔡海生.受潮大型变压器异常试验结果浅析[J].机电工程技术,2005,34(8):131-132.
作者姓名:蔡海生
作者单位:广东电网公司汕头供电分公司,广东,汕头,515041
摘    要:本文总结分析了一台120000/220大型变压器,在投运前已发现进水受潮,在现场条件下进行了干燥处理和电气试验,在试验中发现部分试验结果异常。文中分析了相关试验结果并提出了判断大型变压器进水受潮的方法。

关 键 词:大型变压器  受潮  试验  分析
文章编号:1009-9492(2005)08-0131-02
修稿时间:2005年6月27日

Brief analysis to the abnormal test result of the damping large-scale transformer
CAI Hai-sheng.Brief analysis to the abnormal test result of the damping large-scale transformer[J].Mechanical & Electrical Engineering Technology,2005,34(8):131-132.
Authors:CAI Hai-sheng
Abstract:This article has analyzed the 220kV and 120000kVA large-scale transformer which have been discovered affected with damp before working. The drying measure and electrical experiment have been carried on under the field condition. Part of the test results have been found abnormal in the experiment. In the article the correlating test results have been analyzed and the method is proposed how to judge the large-scale transformer affected with damp.
Keywords:large-scale transformer  affected with damp  test  analysis  
本文献已被 CNKI 维普 万方数据 等数据库收录!