首页 | 官方网站   微博 | 高级检索  
     

Static Adsorption of Xenon on ACF at 257K
引用本文:Haitao ZHANG,Yalong WANG,Xuhui WANG,Lixing ZHANG and Liyun CHENNorthwest Institute of Nuclear Technology,Xi''''an 710024,China. Static Adsorption of Xenon on ACF at 257K[J]. 材料科学技术学报, 2002, 18(6): 522-526
作者姓名:Haitao ZHANG  Yalong WANG  Xuhui WANG  Lixing ZHANG and Liyun CHENNorthwest Institute of Nuclear Technology  Xi''''an 710024  China
作者单位:Haitao ZHANG,Yalong WANG,Xuhui WANG,Lixing ZHANG and Liyun CHENNorthwest Institute of Nuclear Technology,Xi'an 710024,China
摘    要:The static adsorption of xenon on active carbon fiber(ACF) at 257K was measured with ASAP2010 specific surface area and pore diameter distribution instrument by changing the working gas from nitrogen to xenon.Compared with grain activated carbon(GAC),the results were as follows(1)The adsorption performance of Viscose-based ACF(VACF-As)was the best among all absorbents tested.VACF-A3 was the superior xenon absorbent.The performance of pitch-based ACF(PACF-Cs)approached that of GAC,(2) Due to the difference of aperture distribution ,the adsorption performances of ACF with different radices were different under the same experiment conditions even though the specific surface area was similar,(3)There were some differences of adsorptive capacity among ACF absorbents which had the same radic,however there was not definite relationship between their specific surface area and adsorptive capacity,(4)The adsorption of xenon on all kinds of ACF agrees with Langmuir equation.(5)The adsorptiov curves can be fitted with a binomial equation.

关 键 词:碳纤维 氙 吸附 ACF CTBT
收稿时间:2001-07-06

Static Adsorption of Xenon on ACF at 257 K
Haitao ZHANG,Yalong WANG,Xuhui WANG,Lixing ZHANG,Liyun CHEN. Static Adsorption of Xenon on ACF at 257 K[J]. Journal of Materials Science & Technology, 2002, 18(6): 522-526
Authors:Haitao ZHANG  Yalong WANG  Xuhui WANG  Lixing ZHANG  Liyun CHEN
Affiliation:Northwest Institute of Nuclear Technology, Xi'an 710024, China
Abstract:The static adsorption of xenon on active carbon fiber (ACF) at 257 K was measured with ASAP2010 specific surface area and pore diameter distribution instrument by changing the working gas from nitrogen to xenon. Compared with grain activated carbon (GAC), the results were as follows: (1) The adsorption performance of Viscose-based ACF (VACF-As) was the best among all absorbents tested. VACF-A3 was the superior xenon absorbent. The performance of pitch-based ACF (PACF-Cs) approached that of GAC, (2) Due to the difference of aperture distribution, the adsorption performances of ACF with different radics were different under the same experiment conditions even though the specific surface area was similar, (3) There were some differences of adsorptive capacity among ACF absorbents which had the same radic, however there was not definite relationship between their specific surface area and adsorptive capacity, (4) The adsorption of xenon on all kinds of ACF agrees with Langmuir equation, (5) The adsorptive curves can be fitted with a binomial equation.
Keywords:Active carbon fiber   CTBT   Xenon   Adsorption
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《材料科学技术学报》浏览原始摘要信息
点击此处可从《材料科学技术学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号