首页 | 官方网站   微博 | 高级检索  
     


Packaging and testing of a hydrogen safety sensor prototype
Authors:Praveen K. Sekhar  Eric.L. Brosha  Rangachary Mukundan  Hanna Mekonen  Boris Farber  Cortney Kreller  Fernando H. Garzon
Affiliation:1. Nanomaterials and Sensor Laboratory, School of Engineering and Computer Science, Washington State University Vancouver, Vancouver, WA 98686, USA;2. Los Alamos National Laboratory (LANL), Sensors and Electrochemical Devices Group, Los Alamos, NM 87545, USA;3. BJR Sensors, 37920 Flanders Dr, Solon, OH 44139, USA
Abstract:In this article, testing of an electrochemical, potentiometric hydrogen safety sensor is reported within a proposed packaging scheme. Device packaging under static and flow testing conditions are presented. During the static volume sensor testing, the sensors response is compared against a calibrated Gas Chromatography (GC) measurement. Also, a commercial H2 sensor is incorporated into the test chamber to act as a benchmark for the sensor prototype. In the testing phase, H2 selectivity is demonstrated using pulsed discharge technique.
Keywords:Hydrogen   Electrochemical sensor   Mixed potential   Packaging   Pulsed discharge technique