首页 | 官方网站   微博 | 高级检索  
     

基于HPLC的智能电能表通信模块状态监测技术研究
引用本文:贺云隆,宋晓林,白宇峰,杨东华,邓宏昌,朱洋洋,何晓奎. 基于HPLC的智能电能表通信模块状态监测技术研究[J]. 电测与仪表, 2022, 59(10): 190-200
作者姓名:贺云隆  宋晓林  白宇峰  杨东华  邓宏昌  朱洋洋  何晓奎
作者单位:国网陕西省电力有限公司营销服务中心(计量中心),西安710100;国网陕西省电力有限公司,西安710048;北京中宸微电子有限公司,北京100080
基金项目:国网陕西省电力有限公司科技项目(5226YX220003)
摘    要:为了准确抓取低压混装台区HPLC模块通信故障原因,提升数据采集成功率,设计了一种基于高速电力线载波(HPLC)技术的智能电表通信模块状态监测装置。该装置安装于HPLC通信模块和智能电表或集中器之间,通过载波实时自动监听不同厂家的通信模块运行状态信息、通信报文信息和网络噪声信息等,并将携带全网络统一时标的信息实时写入所带的非易失存储器中,利用软件对存储日志进行自动化解析,按照流程来判别故障原因。将该装置应用于异常台区,精准定位了网络故障原因,提高了采集成功率,验证了其实用性。

关 键 词:HPLC  监测装置  SD卡存储  分布式  故障研判
收稿时间:2022-07-04
修稿时间:2022-07-04

esearch on condition monitoring technology of smart meter communication module based on HPLC
Heyunlong,songxiaolin,baiyufeng,yangdonghu,denghongchang,zhuyangyang and hexiaokui. esearch on condition monitoring technology of smart meter communication module based on HPLC[J]. Electrical Measurement & Instrumentation, 2022, 59(10): 190-200
Authors:Heyunlong  songxiaolin  baiyufeng  yangdonghu  denghongchang  zhuyangyang  hexiaokui
Affiliation:State Grid Shaanxi Electric Power Company Marketing Service Center,State Grid Shaanxi Electric Power Company Marketing Service Center (Measurement Center),State Grid Shaanxi Electric Power Company Limited,State Grid Shaanxi Electric Power Company Marketing Service Center (Measurement Center),Beijing Zhongchen Micro Co., Ltd.,Beijing Zhongchen Micro Co., Ltd.,Beijing Zhongchen Micro Co., Ltd.
Abstract:To accurately grasp the cause of HPLC module communication fault in low-voltage mixed loading station area, improve the success rate of data acquisition, a condition monitoring device of smart meter communication module based on high-speed power line carrier (HPLC) technology is designed. The device is installed between the HPLC communication module and the smart meter or concentrator, which automatically monitors the operation status information, communication message information and network noise information of communication modules from different manufacturers in real time through the carrier wave, the information carrying the unified time scale of the whole network is written into the nonvolatile memory by the device in real time, the software automatically parses storage log and identifies the cause of fault through the process. The device is used in two abnormal stations to accurately locate the cause of network fault and improve acquisition success rate, which verifies its practicability.
Keywords:HPLC   Monitoring device   SD card storage   Distributed   Fault research and judgment