首页 | 官方网站   微博 | 高级检索  
     

红细胞裂解液对CD34^+细胞相对计数的影响
引用本文:巩文玉,刘怡,李蓓,张瑞东,李志刚,吴敏媛. 红细胞裂解液对CD34^+细胞相对计数的影响[J]. 中国实验血液学杂志, 2010, 18(3): 762-765
作者姓名:巩文玉  刘怡  李蓓  张瑞东  李志刚  吴敏媛
作者单位:首都医科大学北京儿童医院血液病中心,北京,100045
摘    要:摘要为了研究红细胞裂解液对CD34^+细胞相对计数结果的影响,对37份外周血干细胞采集物进行CD34一PE及CD45一FITCx/.色免疫荧光染色后用FACS裂解液(FACS^TM lysingsolution,FACS)、IOTest3裂解液(IOTest3lysingsolution,IOTest)及自配裂解液溶解红细胞,采用洗涤程序和运用ISHAGE设门策略,检测CD34^+细胞相对数,同时记录细胞的前向散射(forwardscatter,FSC)、侧向散射(sidescatter,sSC)信号及CD45^+细胞百分比。结果表明,FACS处理的样本CD34^+细胞百分比低于IOTest(0.50±0.42v30.92±0.59,P=0.004);而IOTest与自配红细胞裂解液处理结果的差异无统计学意义(0.92±0.59VS0.95±0.64,P=0.902)。经IOTest裂解后细胞的Fsc、SSC信号均显著高于FACS(P〈0.01)。IOTest裂解后的样本CD45^+细胞百分比低于FACS。WBC数的多少与CD34^+细胞百分比不存在相关关系(rs=0.192,P=0.357)。结论:某些红细胞裂解液对CD34等抗原阳性细胞的相对计数确有不良影响,用流式细胞术检测或计数时应慎重选择红细胞裂解液。

关 键 词:红细胞裂解液  FACS裂解液  IDTest裂解液  CD34^+细胞

Effect of RBC Lysing Solution on CD34 + Cell Counting
GONE Wen-Yu,LIU Yi,LI Bei,ZHANG Rui-Dong,LI Zhi-Gang,WU Min-Yuan. Effect of RBC Lysing Solution on CD34 + Cell Counting[J]. Journal of experimental hematology, 2010, 18(3): 762-765
Authors:GONE Wen-Yu  LIU Yi  LI Bei  ZHANG Rui-Dong  LI Zhi-Gang  WU Min-Yuan
Affiliation:(Center of heamatological Diseases, Beijing Chlidren's Hospital, Capital University of Medical Science, Beijng 100045, China)
Abstract:To investigate whether the RBC lysing solution can affect the results of relative enumeration of CD34 ^+ cells ,37 mobiled peripheral blood apheresis products were stained using CD34-PE and CD45-FITC monoclone antibodies and RBCs were then lysed by two lysing solution commercially available( one named FACSTM Lysing Solution,FACS; another IOTest 3 Lysing Solution, IOTest) and one lysing solution self-prepared. After being processed by lyse-and- then-washed method, samples were detected by FACSCantoTM flow cytometer. The percentages of CD34 ^+ cells were determined based on ISHAGE gating strategy, forward and side scatter (FSC and SSC) characteristics , percentage of CD45 ^+ cells were recorded simultaneously. The results showed that by lyse-and-then-wash method, the percentages of CD34 ^+ ceils in FACS-treated samples were significantly lower compared with that in IOTest-treated samples(0.50 ± 0. 42 vs 0. 92 ± 0.59 ,p = 0.004 ), but no statistical difference was observed between IOTest-treated and ourselves-prepared- treated samples. The intensities of FSC and SSC in cells of IOTest-treated sample were significantly higher compared with that in cells of FACS-treated sample (p 〈 0.01 ). The proportion of CD45 ± cells in IOTest-treated samples was lower than that in FACS-treated samples. The WBC count of samples was not correlated to the amount of CD34 ± cells (rs = 0. 192,p = 0. 357). It is concluded that the red cell lysing solution shows unexpected effect on detecting and counting CD34^+ cells, prudence should be taken to select such reagents at FCM performance. Key words RBC lysing solution; FACS lysing solntion; IOTest lysing solution; CD34 ^+ cell
Keywords:
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号