首页 | 官方网站   微博 | 高级检索  
     


Comparison of univariate and multivariate calibration for the determination of micronutrients in pellets of plant materials by laser induced breakdown spectrometry
Authors:Jez Willian Batista Braga  Lilian Cristina Trevizan  Lidiane Cristina Nunes  Iolanda Aparecida Rufini  Dário Santos Jr  Francisco José Krug
Affiliation:1. Instituto de Química, Universidade de Brasília, Campus Universitário Darcy Ribeiro, 70904-970, Brasília-DF, Brazil;2. Centro de Energia Nuclear na Agricultura, Universidade de São Paulo, Av. Centenário 303, 13416-000, Piracicaba-SP, Brazil;3. Departamento de Química, Universidade Federal de São Carlos, Rod. Washington Luís, km 235, 13565-905, São Carlos-SP, Brazil;4. Universidade Federal de São Paulo, Diadema-SP, Brazil
Abstract:The application of laser induced breakdown spectrometry (LIBS) aiming the direct analysis of plant materials is a great challenge that still needs efforts for its development and validation. In this way, a series of experimental approaches has been carried out in order to show that LIBS can be used as an alternative method to wet acid digestions based methods for analysis of agricultural and environmental samples. The large amount of information provided by LIBS spectra for these complex samples increases the difficulties for selecting the most appropriated wavelengths for each analyte. Some applications have suggested that improvements in both accuracy and precision can be achieved by the application of multivariate calibration in LIBS data when compared to the univariate regression developed with line emission intensities. In the present work, the performance of univariate and multivariate calibration, based on partial least squares regression (PLSR), was compared for analysis of pellets of plant materials made from an appropriate mixture of cryogenically ground samples with cellulose as the binding agent. The development of a specific PLSR model for each analyte and the selection of spectral regions containing only lines of the analyte of interest were the best conditions for the analysis. In this particular application, these models showed a similar performance, but PLSR seemed to be more robust due to a lower occurrence of outliers in comparison to the univariate method. Data suggests that efforts dealing with sample presentation and fitness of standards for LIBS analysis must be done in order to fulfill the boundary conditions for matrix independent development and validation.
Keywords:LIBS  Multivariate calibration  PLSR  Plant material  Micronutrient
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号