首页 | 官方网站   微博 | 高级检索  
     

用henke X光源标定Kodak SWR底片的响应曲线
引用本文:何安,何绍堂. 用henke X光源标定Kodak SWR底片的响应曲线[J]. 强激光与粒子束, 1991, 3(4): 493-497
作者姓名:何安  何绍堂
作者单位:西南核物理与化学研究所(何安,何绍堂,沈华忠,祁兰英),西南核物理与化学研究所(庄秀群)
摘    要:利用Henke X光源,通过电子激发方式,获得了C的K_a线(277eV)和Mo的L线(193eV),通过X光激发方式,获得了Al的K_a线(1.5keV)和Ti的K_a线(4.5keV)。利用流气式正比计数管监测X射线强度,测得了Kodak SWR底片对以上四种能量的X光的响应曲线。

关 键 词:底片  响应曲线  激光  等离子体  诊断

SENSITIVITY CURVE CALIBRATION OF KODAK SWR X-RAY FILM
He An,He Shaotang,Shen Huazhong,Qi Lanying,and Zhuang Xiuqun. SENSITIVITY CURVE CALIBRATION OF KODAK SWR X-RAY FILM[J]. High Power Laser and Particle Beams, 1991, 3(4): 493-497
Authors:He An  He Shaotang  Shen Huazhong  Qi Lanying  and Zhuang Xiuqun
Affiliation:Southwest Institute of Nuclear and Chemistry
Abstract:On a Henke X-ray source we produced Ka line of C (277eV) and L line of Mo, and Ka line of Al (l.5keV) and Ka line of Ti (4.5keV) by X-ray excition. The X-ray intensities were monitored by proportional counters, we obtained sensitivity curves of Kodak SWR X-ray film for these different energy X rays.
Keywords:sensitivity curve of film. Henke X-ray source   proportional counter   characteris-tic X-ray spectra.  
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号