摘    要:Three space vector pulse width modulation (SVPWM) schemes, called 7-segment space vector modulation (SVM), 5-segment SVM and 3-segment SVM are studied in this paper. The basic principle of SVPWM is presented. The switching sequence of different scheme is described. The modulation signals, DC bus voltage utilization, and output line voltage harmonic of these schemes are analyzed by the MATLAB software with different modulation index M and frequency modulation index N. The simulation results are analyzed and show that discontinuous modulating functions lead a reduction of switching actions. The DC bus voltage utilization of three schemes is almost the same. For all three SVM, the frequency modulation index N will affect the harmonic characteristic, and the modulation index M will affect DC bus voltage utilization and the harmonic content. The experiment is implemented by the DSP of TMS320F2812. The results validate three algorithms and the simulation.

关 键 词:空间矢量  脉冲幅  开关  谐波  电压
修稿时间:2006-01-15

Comparison of Three SVPWM Strategies
Wei-Feng Zhang Yue-Hui Yu.Comparison of Three SVPWM Strategies[J].Journal of Electronic Science Technology of China,2007,5(3):283-287.
Authors:Wei-Feng Zhang  Yue-Hui Yu
Abstract:Three space vector pulse width modulation (SVPWM) schemes, called 7-segment space vector modulation (SVM), 5-segment SVM and 3-segment SVM are studied in this paper. The basic principle of SVPWM is presented. The switching sequence of different scheme is described. The modulation signals, DC bus voltage utilization, and output line voltage harmonic of these schemes are analyzed by the MATLAB software with different modulation index M and frequency modulation index N. The simulation results are analyzed and show that discontinuous modulating functions lead a reduction of switching actions. The DC bus voltage utilization of three schemes is almost the same. For all three SVM, the frequency modulation index N will affect the harmonic characteristic, and the modulation index M will affect DC bus voltage utilization and the harmonic content. The experiment is implemented by the DSP of TMS320F2812. The results validate three algorithms and the simulation.
Keywords:DC bus voltage utilization  harmonic  switching loss  switching sequence  space vector pulse width modulation  
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号