首页 | 官方网站   微博 | 高级检索  
     

评估SPECT测定不同年龄段健康人肾小球滤过率的准确性
引用本文:麻广宇,邵明哲,陈英茂,陈云爽,徐白萱,田嘉禾,孙雪峰.评估SPECT测定不同年龄段健康人肾小球滤过率的准确性[J].中国医学装备,2013,10(6):5-8.
作者姓名:麻广宇  邵明哲  陈英茂  陈云爽  徐白萱  田嘉禾  孙雪峰
作者单位:1. 解放军总医院核医学科,北京,100853
2. 解放军总医院肾内科,北京,100853
基金项目:国家973项目(2013CB530800)"内脏器官衰老与相关老年疾病防治的基础研究"
摘    要:目的:评估SPECT测定不同年龄段健康人肾小球滤过率(GFR)的准确性。方法:以232例北京地区社区健康居民为研究对象,分别采用双血浆法和99Tcm-二亚乙基三胺五乙酸(99Tcm-DTPA)肾动态显像法测定肾GFR(GFRdt和GFRGates)。以GFRdt为参照标准,分析比较SPECT测定20~29岁、30~39岁、40~49岁、50~59岁、60~69岁及>70岁的6个不同年龄组健康人肾小球率过滤的准确性。结果:①6个不同年龄组所得GFRGates与GFRdt均具有显著性差异。②6个不同年龄组所得GFRGates均明显低于GFRdt,其中30~39岁年龄段GFRGates与GFRdt的差异最大,差异均值为(-34.26±20.79);>70岁年龄组GFRGates与GFRdt的差异最小,差异均值为(-9.48±10.85)。③30~39岁组GFRGates与GFRdt相关性(r=0.42)最差;>70岁组GFRGates与GFRdt相关性(r=0.81)最好。结论:SPECT测定20~49岁健康人GFR的准确性较差,测定≥50岁健康人GFR的准确性较好,其中≥70组准确性最好。

关 键 词:肾小球滤过率  放射性核素显像法  双血浆法  健康人  准确性

Estimate the accuracy of SPECT determination glomerular filtration rate in different age healthy people
Affiliation:MA Guang-yu,SHAO Ming-zhe,CHEN Ying-mao,et al Department of Nuclear Medicine,Chinese PLA Genaral Hospital,Beijing 100853,China.
Abstract:Objective: To estimate the accuracy of SPECT determination glomerular filtration rate in different age healthy groups. Methods: Totally 232 Beijingcommunity health residents were selected as the research subjects. Two-sample method and "Tc'"-DTPA dynamic renal imaging were usea Ior determination of GFR (GFRdt and GFR6ates, respectively). GFRdt as the reference standard, compare the accuracy of six different age groups GFR~ate~ which get by SPECT. Results: ~There were significant differences between GFRdt and GFRGat~ on six different age groups. ~GFRG,,~ from Six different age groups were significantly lower than those of GFRdt. The difference in the group of 50-59years between GFRdt and GFRGat~ is maximum, the mean difference is (-54.26_-_20.79) ml/(mino 1.75m)2. The difference in the group of _〉70years between GFRat and GFR6ates is minimum, the mean difference is (-25.62_+ 18.60) ml/(min* 1.75m)2. ~GFRdt and GFR6,tes derived from the group 50-39years had the worst correlation (r=0.42). GFRdt and GFR~ate~ derived from the group -~70years had the best correlation (r=0.81). Conclusion: The accuracy of GFR which got by SPECT is poor in 20-49years health group, it is better in _〉50 Years health group, while it is the best in 〉-70 years health group.
Keywords:Glomerular filtration rate  Radionuclide imaging method  Dual plasma sample method  Health people  Accuracy
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号