首页 | 官方网站   微博 | 高级检索  
     


Early nociceptive evoked potentials (NEPs) recorded from the scalp
Affiliation:1. Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DINOGMI), University of Genova, L.go Daneo 3, 16132 Genova, Italy;2. Department of Human Neuroscience, Sapienza University, Viale dell''Università 30, 00185 Roma, Italy;3. Department of Neuroscience, Ospedale Policlinico San Martino, L.go R. Benzi 10, 16132 Genova, Italy
Abstract:ObjectiveNeurophysiological investigation of nociceptive pathway has so far been limited to late cortical responses. We sought to detect early components of the cortical evoked potentials possibly reflecting primary sensory activity.MethodsThe 150 IDE micropatterned electrode was used to selectively activate Aδ intraepidermic fibres of the right hand dorsum in 25 healthy subjects and 3 patients suffering from trigeminal neuralgia. Neurographic recordings were performed to assess type of stimulated fibres and check selectivity. Cortical evoked potentials were recorded from C3′-Fz and Cz-Au1.ResultsNeurographic recordings confirmed selective activation of Aδ fibres. Early components were detected after repetitive stimulation (0.83/s rate and 250–500 averages); the first negative component occured at 40 ms (N40) on the contralateral scalp.ConclusionsThe provided data support the hypothesis that N40 could be the cortical primary response conducted by fast Aδ fibres.SignificanceThis is the first report of early, possibly primary, cortical responses in humans by nociceptive peripheral stimulation. Although not perfected yet to allow widespread diagnostic use, this is probably the only method to allow fully objective evaluation of the nociceptive system, with important future implications in experimental and clinical neurophysiology.
Keywords:Neurophysiology  Nociception  Pain  Evoked Potentials  Primary response  Micropatterned  150 IDE"}  {"#name":"keyword"  "$":{"id":"k0040"}  "$$":[{"#name":"text"  "_":"150 μm InterDigitated Electrode  1000 IDE"}  {"#name":"keyword"  "$":{"id":"k0050"}  "$$":[{"#name":"text"  "_":"1000 μm InterDigitated Electrode  IASP"}  {"#name":"keyword"  "$":{"id":"k0060"}  "$$":[{"#name":"text"  "_":"International Association for the Study of Pain  LEP(s)"}  {"#name":"keyword"  "$":{"id":"k0070"}  "$$":[{"#name":"text"  "_":"Laser Evoked Potential(s)  PREP(s)"}  {"#name":"keyword"  "$":{"id":"k0080"}  "$$":[{"#name":"text"  "_":"Pain Related Evoked Potential(s)  SEP(s)"}  {"#name":"keyword"  "$":{"id":"k0090"}  "$$":[{"#name":"text"  "_":"Somatosensory Evoked Potential(s)  NEP(s)"}  {"#name":"keyword"  "$":{"id":"k0100"}  "$$":[{"#name":"text"  "_":"Nociceptive Evoked Potential(s)  VAS"}  {"#name":"keyword"  "$":{"id":"k0110"}  "$$":[{"#name":"text"  "_":"Visual Analog Scale
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号