首页 | 官方网站   微博 | 高级检索  
     

三相三线静止式多功能电能表错误接线时退补电量算法研究
引用本文:丁恒春,庞富宽,田海亭,姜振宇,李文文.三相三线静止式多功能电能表错误接线时退补电量算法研究[J].电测与仪表,2016,53(1):70-74.
作者姓名:丁恒春  庞富宽  田海亭  姜振宇  李文文
作者单位:国网冀北电力有限公司电力科学研究院,北京100045;华北电力科学研究院有限责任公司,北京100045
摘    要:电能的准确计量关系到电力企业和广大电力用户的切身利益。如果电能计量装置接线错误,将会引起计量差错,甚至造成经济纠纷。在多数情况下,为了纠正计量差错,首先要确定更正系数,接着要核算退补电量。由于更正系数往往与功率因数角有关,因此可能是实时变化的,这样将给退补电量的核算带来误差或不便。文中以错误接线时三相三线静止式多功能电能表所计有功电量和无功电量为数据源,通过相量分析推导出了实际有功电量的计算公式,提高了退补电量核算的准确性与便捷性。

关 键 词:三相三线电能表  错误接线  退补电量  功率因数
收稿时间:2015/10/10 0:00:00
修稿时间:2015/10/10 0:00:00

Error-wiring Correction Approach for Three-phase Three-wire Static Multifunctional Electric Energy Meter
Ding Hengchun,Pang Fukuan,Tian Haiting,Jiang Zhenyu and Li Wenwen.Error-wiring Correction Approach for Three-phase Three-wire Static Multifunctional Electric Energy Meter[J].Electrical Measurement & Instrumentation,2016,53(1):70-74.
Authors:Ding Hengchun  Pang Fukuan  Tian Haiting  Jiang Zhenyu and Li Wenwen
Affiliation:State Grid Jibei Electric Power Company Limited Power Research Institute,,North China Electric Power Research Institute CoLtd,Beijing,State Grid Jibei Electric Power Company Limited Power Research Institute,,North China Electric Power Research Institute CoLtd,Beijing,State Grid Jibei Electric Power Company Limited Power Research Institute,,North China Electric Power Research Institute CoLtd,Beijing,State Grid Jibei Electric Power Company Limited Power Research Institute,,North China Electric Power Research Institute CoLtd,Beijing,State Grid Jibei Electric Power Company Limited Power Research Institute,,North China Electric Power Research Institute CoLtd,Beijing
Abstract:Accurate measurement of electric energy is related to the immediate interests of the general electric power enterprise and users. If there is an incorrect wiring event of the electric energy metering device, it will cause metering mistake and even may cause economic disputes. In order to correct metering mistakes in most cases, the first is to determine the correction coefficient, then calculate the electricity quantity correction. Because of the correction coefficient is often associated with the power factor angle, it is probably real-time changing, which will bring misalignment or inconvenience of calculation. Based on the active and reactive electricity of the error wiring three-phase three-wire static multifunctional electric energy meter, this paper deduces the expression of actual active electricity by means of vector analysis, what makes the calculation of the active electricity mistake more accurate and efficient.
Keywords:three-phase three-wire electric energy meter  incorrect wiring  electricity quantity correction  power factor