摘    要:目的 观察高分辨率MRI平行于视神经的轴位及斜矢状位重建测量国人正常成年男性视神经长度的差异.方法 对500例无视力障碍的中国成年男性志愿者行全脑T1加权三维磁化强度预备梯度回波序列扫描.采用Aquariusws软件重建轴位及斜矢状位MR图像,测量各段视神经长度,比较两种重建方法的差异性.结果 平行于视神经的轴位及斜矢状位MRI均可清晰显示视神经的结构.轴位测量视神经全长为(43.58±3.41)mm,斜矢状位为(42.13±3.26)mm,轴位测量值大于斜矢状位(P<0.05).结论 高分辨率MRI可清晰显示视神经整体轮廓,准确测量视神经长度,平行于视神经的轴位重建是测量视神经长度的最佳方法之一.

关 键 词:视神经  磁共振成像  成像  三维
收稿时间:2009-11-19
修稿时间:2010-02-02

Measurement of the length of optic nerve in normal adult male Chinese with high-resolution MR
QI Yan,CHEN Nan,WANG Xing,YANG Fang,ZHANG Li,PENG Guang-ming,ZHUO Yan,CHEN Lin,OU Shan-xing and LI Kun-cheng. Measurement of the length of optic nerve in normal adult male Chinese with high-resolution MR[J]. Chinese Journal of Medical Imaging Technology, 2010, 26(5): 840-843
Authors:QI Yan  CHEN Nan  WANG Xing  YANG Fang  ZHANG Li  PENG Guang-ming  ZHUO Yan  CHEN Lin  OU Shan-xing  LI Kun-cheng
Affiliation:Department of Radiology, General Hospital of Guangzhou Military Command of PLA,Guangzhou 510010, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;Department of Radiology, General Hospital of Guangzhou Military Command of PLA,Guangzhou 510010, China;Department of Radiology, General Hospital of Guangzhou Military Command of PLA,Guangzhou 510010, China;Department of Radiology, General Hospital of Guangzhou Military Command of PLA,Guangzhou 510010, China;State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics,Chinese Academy of Sciences, Beijing 100101, China;State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics,Chinese Academy of Sciences, Beijing 100101, China;Department of Radiology, General Hospital of Guangzhou Military Command of PLA,Guangzhou 510010, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China
Abstract:Objective To compare the difference of the length of optic nerve in normal adult male Chinese measured on axial or oblique sagittal reconstruction with high-resolution MRI. Methods Totally 500 adult male Chinese without visual dysfunction underwent brain MR scan with T1 weighted three-dimensional magnetization-prepared rapid acquisition gradient-echo sequence. The reconstructed images of axial and oblique sagittal section parallel with optic nerve were obtained with Aquariusws 3D analysis software. The leng...
Keywords: Optic nerve  Magnetic resonance imaging  Imaging, three-dimensional