肺动脉瓣球囊扩张术前后应用多普勒超声估测跨瓣压差的临床价值研究
引用本文:胡海波,蒋世良,凌坚,谢若兰,黄连军,赵世华,徐仲英,郑宏,戴汝平. 肺动脉瓣球囊扩张术前后应用多普勒超声估测跨瓣压差的临床价值研究[J]. 中国介入心脏病学杂志, 2002, 10(1)
作者姓名:胡海波  蒋世良  凌坚  谢若兰  黄连军  赵世华  徐仲英  郑宏  戴汝平
作者单位:中国医学科学院,中国协和医科大学,阜外心血管病医院,心血管病研究所放射科,北京,100037
摘    要:目的 通过与心导管测量对比来评价经皮肺动脉瓣球囊成形术(PBPV)前后应用Doppler超声心动图估测跨瓣压差的临床价值。方法 对178例患者在行PBPV术前利用Doppler测量肺动脉瓣跨瓣压差(△P’),与相应的心导管测量值(△P)作相关性分析;并利用Doppler对PBPV术后48例患者进行了4~102个月(平均19.5个月)的随访。结果Doppler测量的△P’值与导管测量的△P值之间有着良好的直线相关性,r值为0.80,P<0.05;随访中Doppler测量的△P’值与PBPV术后即刻导管测量的△P值之间差异无显著性(P=0.05)。结论Doppler超声作为一种准确、无创、简便而有效的检查方法,对估计PBPV术前肺动脉瓣狭窄程度,评价术后疗效有较高的临床应用价值。

关 键 词:血管成形术  经皮  肺动脉瓣  肺动脉瓣狭窄  超声描记术  多普勒

Application in percutaneous balloon pulmonary valvuloplasty (PBPV) of Doppler echocardiography: compared with catheterization HU Haibo, JIANG Shiliang, LING Jian, et al. Department of Radiology, Cardiovascular Institute and Fu Wai Hospital, Chinese Academ
HU Haibo,JIANG Shiliang,LING Jian,et al.. Application in percutaneous balloon pulmonary valvuloplasty (PBPV) of Doppler echocardiography: compared with catheterization HU Haibo, JIANG Shiliang, LING Jian, et al. Department of Radiology, Cardiovascular Institute and Fu Wai Hospital, Chinese Academ[J]. Chinese Journal of Interventional Cardiology, 2002, 10(1)
Authors:HU Haibo  JIANG Shiliang  LING Jian  et al.
Affiliation:HU Haibo,JIANG Shiliang,LING Jian,et al. Department of Radiology,Cardiovascular Institute and Fu Wai Hospital,Chinese Academy of Medical Sciences and Peking Union Medical College,Beijing 100037,China
Abstract:Objective To assess the value of Doppler applicating in estimating the gradients across pulmonic valve (PG) pre-valvuloplasty and post-valvuloplasty (compared with catheterization) . Methods PBPV was performed on one hundred and seventy-eight patients with valvular pulmonary stenosis. The gradient across pulmonic valve was measured by Doppler and catheterization before valvuloplasty respectively, and the linear correlation between two methods was analyzed. Forty-eight patients were follow up for 4-102 months (average 19.5 months) by Doppler examination. Results There was a good correlation between the simultaneous pressure gradient estimated by Doppler and the peak-to-peak pressure gradient measured by catheterization (r = 0.80). And there was no significant difference between the PG estimated by Doppler in follow-up and the PG measured by catheterization after valvuloplasty immediately (P = 0.05) . Conclusion As a noninvasive. accurate and simple method, Doppler would play a great role in estimating degree of stenosis pre-valvuloplasty and assessing curative effect post- valvuloplasty.
Keywords:Percutaneous balloon pulmonary valvuloplasty  Valvular pulmonary stenosis  Doppler echocardiography