Transcatheter closure of the patent arterial duct using the Flipper coil in a premature infant weighing 1,400 g: a case report.
Authors:Roopa Thukaram  William A Suarez  Sreekanthan Sundararaghavan
Affiliation:Division of Cardiology Mercy Children's Hospital, Toledo, OH 43608, USA.
Abstract:A symptomatic 1,400 g premature triplet underwent successful transcatheter coil embolization of patent arterial duct using the umbilical artery. One 3 mm x 3 cm Flipper coil was used with no angiographic residual shunt. To the best of our knowledge, this is one of the smallest preterm infants to undergo this transcatheter procedure.
Keywords:low birth weight  detachable coil  patent arterial duct  transcatheter closure