首页 | 官方网站   微博 | 高级检索  
     

贮槽液氮质量波动原因查找总结
引用本文:李军.贮槽液氮质量波动原因查找总结[J].深冷技术,2013(6):60-63.
作者姓名:李军
作者单位:福建炼化林德气体有限责任公司,福建省泉州市泉港区362800
摘    要:针对1500 m3液氮贮槽氧含量缓慢上升的现象,从分析仪、贮槽进液纯度以及贮槽周围空气进入三方面分析了原因,并采取措施加以解决。介绍故障现象和原因查找过程。

关 键 词:液氮贮槽  纯度  分析仪  快速切断阀  标准气

Summary of finding out the causes for quality fluctuation of liquefied nitrogen in storage tank
Li Jun.Summary of finding out the causes for quality fluctuation of liquefied nitrogen in storage tank[J].Cryogenic Technology,2013(6):60-63.
Authors:Li Jun
Affiliation:Li Jun (Fufian Refining Chemical Corporation Linde Gas Co. , Ltd. , Quangang District, Quanzhou 362800, Fujian, P. R. China)
Abstract:The causes for slow increase of oxygen content in 1500 m3 liquefied nitrogen in storage tank are analyzed from the analyzer, purity of liquid entering the storage tank, and admission of air surrounding the storage tank, and measures are taken to solve the said trouble. Here, the trouble and the course to find out the causes are described.
Keywords:Liquefied nitrogen storage tank  Purity  Analyzer  Fast cut-off valve  Standard gas
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号