首页 | 官方网站   微博 | 高级检索  
     

Determination of Tetracyclines in Honey Using Liquid Chromatography with Ultraviolet Absorbance Detection and Residue Confirmation by Mass Spectrometry
引用本文:刘艳 徐锦忠 丁涛 李公海. Determination of Tetracyclines in Honey Using Liquid Chromatography with Ultraviolet Absorbance Detection and Residue Confirmation by Mass Spectrometry[J]. 中国化学, 2007, 25(9): 1294-1299. DOI: 10.1002/cjoc.200790240
作者姓名:刘艳 徐锦忠 丁涛 李公海
作者单位:Food Laboratory, Jiangsu Entry-Exit Inspection and Quarantine Bureau, Nanjing, Jiangsu 210001, China
摘    要:A determination method has been optimized and validated for the simultaneous analysis of tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and doxycycline (DC) in honey. Tetracyclines (TCs) were removed from honey samples by chelation with metal ions bound to small Chelating Sepharose Fast Flow columns and eluted with Na2EDTA-Mcllvaine pH 4.0 buffers. Extracts were further cleaned up by Oasis HLB solid-phase extraction (SPE), while other solid-phase extraction cartridges were compared. Chromatographic separation was achieved using a polar end-capped C 18 column with an isocratic mobile phase consisting of oxalic acid, acetonitrile and methanol. LC with ultraviolet absorbance at 355 nm resulted in the quantitation of all four tetracycline residues from honey samples fortified at 15, 50, and 100 ng/g, with liner ranges for tetracyclines of 0.05 to 2 μg/mL. Mean recoveries for tetracyclines were greater than 50% with R.S.D. values less than 10% (n= 18). Detection limits of 5, 5, 10, 10 ng/g for oxytetracycline, tetracycline, chlortetracycline and doxycycline, respectively and quantitation limits of 15 ng/g for all the four tetracyclines were determined. Direct confirmation of the four residues in honey (2-50 ng/g) was realized by liquid chromatography-tandem mass spectrometry (LC/MS/MS). The linear ranges of tetracyclines determined by LC/MS/MS were between 5 to 300 ng/mL, with the linear correlation coefficient r〉 0.995. The limits of detection of 1 to 2 ng/g were obtained for the analysis of the TCs in honey.

关 键 词:四环素  蜂蜜  金属螯化亲和力  色谱法  紫外线吸收法
修稿时间:2006-09-06

Determination of Tetracyclines in Honey Using Liquid Chromatography with Ultraviolet Absorbance Detection and Residue Confirmation by Mass Spectrometry
LIU Yan, XU Jin-Zhong, DING Tao, LI Gong-Hai,. Determination of Tetracyclines in Honey Using Liquid Chromatography with Ultraviolet Absorbance Detection and Residue Confirmation by Mass Spectrometry[J]. Chinese Journal of Chemistry, 2007, 25(9): 1294-1299. DOI: 10.1002/cjoc.200790240
Authors:LIU Yan   XU Jin-Zhong   DING Tao   LI Gong-Hai  
Affiliation:Food Laboratory, Jiangsu Entry-Exit Inspection and Quarantine Bureau, Nanjing, Jiangsu 210001, China
Abstract:A determination method has been optimized and validated for the simultaneous analysis of tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and doxycycline (DC) in honey. Tetracyclines (TCs) were removed from honey samples by chelation with metal ions bound to small Chelating Sepharose Fast Flow columns and eluted with Na2EDTA‐Mcllvaine pH 4.0 buffers. Extracts were further cleaned up by Oasis HLB solid‐phase extraction (SPE), while other solid‐phase extraction cartridges were compared. Chromatographic separation was achieved using a polar end‐capped C18 column with an isocratic mobile phase consisting of oxalic acid, acetonitrile, and methanol. LC with ultraviolet absorbance at 355 nm resulted in the quantitation of all four tetracycline residues from honey samples fortified at 15, 50, and 100 ng/g, with liner ranges for tetracyclines of 0.05 to 2 µg/mL. Mean recoveries for tetracyclines were greater than 50% with R.S.D. values less than 10% (n=18). Detection limits of 5, 5, 10, 10 ng/g for oxytetracycline, tetracycline, chlortetracycline and doxycycline, respectively and quantitation limits of 15 ng/g for all the four tetracyclines were determined. Direct confirmation of the four residues in honey(2–50 ng/g) was realized by liquid chromatography‐tandem mass spectrometry (LC/MS/MS). The linear ranges of tetracyclines determined by LC/MS/MS were between 5 to 300 ng/mL, with the linear correlation coefficient r>0.995. The limits of detection of 1 to 2 ng/g were obtained for the analysis of the TCs in honey.
Keywords:tetracyclines   honey   metal chelate affinity chromatography   LC/MS/MS