首页 | 官方网站   微博 | 高级检索  
     


A new heat fluxmeter
Authors:J L Gaillard  F Gallin  B Wojtyniak
Affiliation:(1) Laboratoire D'electricité Industrielle, Conservatoire National des Arts et Métiers, 292 Rue Saint Martin, 75141 Paris Cedex 03, France
Abstract:The dynamic measurement of beat flux gives a lagged and out of shape electrical response due to the heat transfer through the materials. So, it is necessary to use dynamic correctors to get the real response.To reduce the length of the thermal conductors, we propose to generate the useful electric signal perpendiculary to the heat flux by means of a magnetic induction field.We built a new heat fluxmeter, fitted to a 15 cm cell and based on this thermomagnetoelectric effect. Its main intrinsic time constant is 25 seconds and its sensibility at room temperature is 0.6MgrV/mW.
Zusammenfassung Die dynamische Messung eines WÄrmeflusses ergibt ein zeitlich verzögertes und amplitudenmÄssig verÄndertes elektrisches Signal. Mit geeigneten dynamischen elektrischen Korrekturgliedern kann das reale Signal approximiert werden. Zur Verringerung der LÄnge der Messanordung wird ein neues thermomagnetoeletrisches Prinzip vorgeschlagen. Unter Verwendung eines magnetischen Induktionsfeldes senkrecht zum WÄrmefluss wird ein zu diesen beiden Flüssen senkrecht stehendes elektrisches Potential erzeugt.Die Konstruktion dieses WÄrmeflussdetektors wird vorgestellt und die Charakteristik wird diskutiert.