Abstract:A calibration technique for laboratory type polarimetric, bistatic instrumentation radars is presented. It describes the errors induced by the standard radiation transfer approach (I-SRT) in a way similar to that for the monostatic case. A 12-term error correction and absolute polarimetric calibration is performed with two external reference targets. Only the polarimetric bistatic reference of the first target must be theoretically determined. The scattering reference of the second target is determined by a measurement during the calibration process (single reference calibration). The simulation of a third cross-polarization measurement is performed by an antenna rotation and a remeasurement of the second target. Thus all data are gained for the determination of the error terms and measurements of unknown objects can be full polarimetrically calibrated. The procedures are shown for an adapted dihedral corner reflector. Misalignment errors are discussed