Abstract: | Research on the magnetron cavity used in the rubidium atomic frequency standards is developed, through which the main characteristic parameters of the magnetron cavity are studied,mainly including the resonant frequency,quality factor and oscillation mode.The resonant frequency and quality factor of the magnetron cavity were calculated,and the test results of the resonant frequency agreed well with the calculation theory.The test results also show that the resonant frequency of the magnetron cavity can be a... |