首页 | 官方网站   微博 | 高级检索  
     

一起珠光砂堵塞过冷器的故障处理
引用本文:许锦华.一起珠光砂堵塞过冷器的故障处理[J].深冷技术,2010(1):25-27.
作者姓名:许锦华
作者单位:宝钢集团南通钢铁有限公司能源部,江苏省南通市唐闸镇河东北路161号226002
摘    要:在KDON-4500/4500-3型空分设备精馏塔大加温过程中发生管道断裂故障,珠光砂进入纯氮通道堵塞过冷器并造成空分设备停车。介绍为排除故障而对过冷器进行正、反向吹扫的管线流程。阐述了为避免同类故障再次发生,对冷箱内管道、支架所作的改进措施以及精馏塔加温吹扫的优化操作。

关 键 词:空分设备  冷箱  管道  过冷器  堵塞  珠光砂

Treatment of trouble of blocking of sub-cooler by pearlite
Xu Jinhua.Treatment of trouble of blocking of sub-cooler by pearlite[J].Cryogenic Technology,2010(1):25-27.
Authors:Xu Jinhua
Affiliation:Xu Jinhua(Energy Department,Nantong Iron & Steel Co.,Ltd.,Baosteel Group,161 Hedong North Road,Tangzha Town,Nantong 226002,Jiangsu,P.R.China)
Abstract:During overall warming of the rectification column of Model KDON4500/4500-3 air separation plant,the pipeline breakage results in entrance of pearlite into the purified nitrogen passage,blocking of the sub-cooler and shutdown of the air separation plant.Here,the pipeline process of forwards and backwards purging the sub-cooler for troubleshooting is briefed.The improving measures for pipelines and supports inside the cold box and the optimized operation of warming purging of the rectification column for avo...
Keywords:Air separation plant  Cold box  Pipeline  Sub-cooler  Blocking  Pearlite  