首页 | 官方网站   微博 | 高级检索  
     


Numerical study of a hybrid ventilation system for single family houses
Authors:David Jreijiry   Ahmad Husaunndee  Christian Inard  
Affiliation:aJacobs France, 86 rue Regnault, F75640 Paris Cedex 13, France;bCentre Scientifique et Technique du Bâtiment, 84 Avenue Jean Jaurès, F77447 Marne la Vallée Cedex 2, France;cLEPTAB, Université La Rochelle, Avenue Michel Crépeau, F17042 La Rochelle Cedex, France
Abstract:The main objective of this study is to develop and test hybrid ventilation systems and control strategies that are suitable for residential buildings. Two ventilation systems were modelled: a mechanical extract ventilation system (called the reference system) and a hybrid low pressure ventilation system that can support two different types of demand control strategies (occupancy detection and CO2 concentration). The newly developed models were assembled with the existing thermal models of the SIMBAD Building and HVAC Toolbox developed by the CSTB.A single family house located in Athens (Greece), Nice (France), Trappes (France) and finally Stockholm (Sweden) was considered as the case study. Yearly simulations were performed to assess the performance of the hybrid ventilation control strategies. The assessment criteria used are related to indoor air quality, thermal comfort, energy consumption and stability of control strategies. The results show that the low pressure ventilation system can improve the indoor air quality and reduce the fan energy consumption compared to the reference system while maintaining the same building energy consumption for heating.
Keywords:Hybrid ventilation   Control strategies   Indoor air quality   Numerical simulation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号