首页 | 官方网站   微博 | 高级检索  
     


Seismic design of reduced beam section steel moment connections with bolted web attachment
Authors:Cheol-Ho Lee  Jae-Hoon Kim
Affiliation:Department of Architectural Engineering, Seoul National University, Republic of Korea
Abstract:Recent test results on reduced beam section (RBS) steel moment connections showed that specimens with a bolted web connection tend to perform poorly due to premature brittle fracture of the beam flange at the weld access hole. The measured strain data appeared to indicate that a higher incidence of base metal fracture in bolted web specimens is related, at least in part, to the increased demand on the beam flanges due to the web bolt slippage and the actual load transfer mechanism which is significantly different from that usually assumed in connection design. In this paper, the practice of providing web bolts uniformly along the beam depth was brought into question. A new seismic design procedure, which is more consistent with the actual load path identified from analytical and experimental studies, is proposed. A pilot test specimen designed by following the proposed procedure exhibited sufficient cyclic connection rotation capacity without fracture.
Keywords:Bolted web attachment  Reduced beam section  Steel moment connection  Seismic design
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23