首页 | 官方网站   微博 | 高级检索  
     

热型连铸保温炉流场与温度场模拟及其结构优化
引用本文:赵鸿金,安桂焕,杨斌,张明明,徐高磊,李金德. 热型连铸保温炉流场与温度场模拟及其结构优化[J]. 特种铸造及有色合金, 2012, 32(7): 641-644
作者姓名:赵鸿金  安桂焕  杨斌  张明明  徐高磊  李金德
作者单位:江西理工大学材料科学与工程学院
基金项目:国家自然科学基金资助项目
摘    要:利用CFD软件FLUENT对自制横引式一股四流单晶铜热型连铸保温炉结构进行数值模拟,并提出优化方案。结果表明,现用保温炉的四流连铸出流口单边等距位置结构分布不合理,进流口铜液对靠近进流口位置的1号、3号出流口铜液扰动较大;温度场分布不均匀,进出流口最大温差近5K,且出流口1号、3号与2号、4号存在较大温差。采用双边对称、不等距结构,即进流口与1号、3号出流口距离增大到198mm的方案,炉膛内铜液的流动分布表现合理,各出流口温度几乎一致。

关 键 词:热型连铸  FLUENT  数值模拟  结构优化

Numerical Simulation of Flow Field and Temperature Field in Heated Mould Continuous Casting Furnace and its Structure Optimization
Zhao Hongjin , An Guihuan , Yang Bin , Zhang Mingming , Xu Gaolei , Li Jinde. Numerical Simulation of Flow Field and Temperature Field in Heated Mould Continuous Casting Furnace and its Structure Optimization[J]. Special Casting & Nonferrous Alloys, 2012, 32(7): 641-644
Authors:Zhao Hongjin    An Guihuan    Yang Bin    Zhang Mingming    Xu Gaolei    Li Jinde
Affiliation:(School of Materials Science & Engineering,Jiangxi University of Science & Technology)
Abstract:The flow field and temperature field in the self-developed horizontal-pulling heated mould continuous casting furnace with one-inlet to for-outlets for single crystallization copper were simulated by the Fluent software of CFD,and ite structure optimization was conducted.The results show that distribution of equal-distance location structure of outlets is un-reasonable at the holding furnace,where there exists obvious turbulence of inlet copper melt on outlet copper melt at No.1 and No.3 near inlet position.Meanwhile,the un-even temperature distribution at the holding furnace can be observed,and the maximum temperature difference between the inlet and outlets reaches 5 K,and there is a larger temperature difference between outlets of No.1,No.3 and No.2,No.4.Through designing two-side symmetric and unequal distance structure,where the distance of inlets from outlets of No.1 and No.3 is increased to 198 mm,flow and temperature distribution of liquid copper in the holding furnace exhibit desirable,and the temperature difference of outlets can be ignored.
Keywords:Heated Mould Continuous Casting  Fluent  Numerical Simulation  Structure Optimization