摘    要:日盲型紫外像增强器在空间光学探测、环境监测、战略国防等方面上具有非常广阔的应用前景,参照微光像增强器信噪比测试原理,设计了紫外像增强器信噪比测试系统,并给出其测试条件,利用研制的信噪比测试仪研究了微通道板两端电压对日盲型紫外像增强器信噪比的影响,测量了其关系曲线。结果表明,在小于850 V区域内,紫外像增强器的输出信噪比随着MCP两端电压的增大而增大;当超过850 V时,MCP两端电压增大,紫外像增强器的输出信噪比基本维持不变。

关 键 词:微通道板    紫外像增强器    信噪比    电压

Relationship between voltage of MCP and signal-to-noise ratio of UV image intensifier
WU Xing-lin , QIU Ya-feng , QIAN Yun-sheng , LIU Zhao-lu , CHENG Hong-chang.Relationship between voltage of MCP and signal-to-noise ratio of UV image intensifier[J].Journal of Applied Optics,2013,34(3):494-497.
Authors:WU Xing-lin  QIU Ya-feng  QIAN Yun-sheng  LIU Zhao-lu  CHENG Hong-chang
Affiliation:1.School of Mechanics Engineering,Nanjing University of Science and Technology,Nanjing 210094,China;2.School of Electronic Engineering and Optoelectronic Technology,Nanjing University of Science and Technology,Nanjing 210094,China;3.Science and Technology on Low-Light-Level Night Vision Laboratory,Xi-an 710065,China
Abstract:Ultraviolet image intensifier has a very broad application prospects in many fields, such as space optical detection, environmental monitoring, strategic defense, and so on. Signal-to-noise ratio measurement system of ultraviolet image intensifier was designed by reference to the test principle of signal-to noise ratio for UV image intensifier, and its test conditions were provided. The relationship between voltage of MCP and signal-to-noise ratio of UV image intensifier was deeply studied, and its curve is measured by using the development of its own signal-to-noise ratio tester for UV image intensifier. The result shows that in the region of less than 850 V, the output of the signal-to-noise ratio of the ultraviolet image intensifier is increased with the increase of voltage; when the voltage is more than 850 V, the output of the signal-to-noise ratio of the ultraviolet image intensifier is essentially unchanged.