首页 | 官方网站   微博 | 高级检索  
     

Construction and Application of a PVC Membrane Enoxacin Ion-selective Electrode Based on a Needle-shaped Inner Reference Electrode
作者姓名:HUANG Chao-lun *  LI Rui-fen and XIU Rong School of Pharmaceutical Sciences  Hebei Medical University  Shijiazhuang  P. R. China
作者单位:HUANG Chao-lun *,LI Rui-fen and XIU Rong School of Pharmaceutical Sciences,Hebei Medical University,Shijiazhuang 050017,P. R. China
摘    要:IntroductionPVC membrane- coated- wire electrodes areused in the analytical field widely. They are pre-pared usually with platinum wire,silver wire orgraphite rod coated with a PVC thin membranecontaining various active components and plasticiz-ers1— 3 ] .The electrodes have no inner KCl solutionand they are notinfluenced by the sample pressure.Furthermore,they are free from directional selec-tivity when they are installed,and they can be mi-crominiaturized easily. The shortcomings of th…

关 键 词:PVC    离子选择电极  针形成型  容量测定  电化学
收稿时间:2002-12-04

Construction and Application of a PVC Membrane Enoxacin Ion-selective Electrode Based on a Needle-shaped Inner Reference Electrode
HUANG Chao-lun *,LI Rui-fen and XIU Rong School of Pharmaceutical Sciences,Hebei Medical University,Shijiazhuang ,P. R. China.Construction and Application of a PVC Membrane Enoxacin Ion-selective Electrode Based on a Needle-shaped Inner Reference Electrode[J].Chemical Research in Chinese University,2003,19(4):409-412.
Authors:HUANG chao-lun  LI Rui-fen  XIU Rong
Affiliation:School of Pharmaceutical Sciences, Hebei Medical University, Shijiazhuang 050017, P. R. China
Abstract:A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl- ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10-5-1.0×10-2 mol/L. The detection limit was 2.0×10-5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia.
Keywords:Enoxacin  PVC membrane-coated-wire electrode  Ion-selective electrode  Content determination
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《高等学校化学研究》浏览原始摘要信息
点击此处可从《高等学校化学研究》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号