摘    要:对不同气候条件的典型城市进行模拟分析,在选用不同的外墙类型的情况下,模拟得到玻璃幕墙办公建筑年总能耗与窗墙面积比的关系.建筑年总能耗与窗墙比之间存在显著的线性关系,并受到外墙类型的影响,影响程度按照从北到南顺序依次减弱.

关 键 词:玻璃幕墙建筑  外墙类型  窗墙比  总能耗

Influences Analysis of Outer Wall Types Acts on the Relationship between the Total Building Energy Consumption and the Ratio of Window to Wall
TANG Ke-yue,LI De-ying,CAO Yan.Influences Analysis of Outer Wall Types Acts on the Relationship between the Total Building Energy Consumption and the Ratio of Window to Wall[J].Construction Conserves Energy,2008,36(10).
Authors:TANG Ke-yue  LI De-ying  CAO Yan
Affiliation:Beijing University of Civil Engineering and Architecture;Beijing 100044;China
Abstract:Simulation and analysis of the typical city with different climate were carried out, and the relationship between the total energy consumption of the glass wall office buildings and the ratio of window to wall was obtained under the condition of the different types of outer wall. The result shows that the prominent linear relation existed between the total building energy consumption and the ratio of window to wall, which was influenced by the types of the outer wall, and influence degree was gradually weak...
Keywords:glass wall buildings  the types of outer wall  the ratio of window to wall  the total energy consumption  