首页 | 官方网站   微博 | 高级检索  
     

Determination of volatile components in cut tobacco with gas chromatography-mass spectrometry and chemometric resolution
作者姓名:黄兰芳  吴名剑  孙贤军  钟科军  郭紫明  戴云辉  黄可龙  郭方遒
作者单位:Technical Center of Changde Cigarette Factory,Technical Center of Changde Cigarette Factory,Technical Center of Changde Cigarette Factory,Technical Center of Changde Cigarette Factory,Technical Center of Changde Cigarette Factory,Technical Center of Changde Cigarette Factory,School of Chemistry and Chemical Engineering Central South University,School of Chemistry and Chemical Engineering Central South University,Changde 415000 China School of Chemistry and Chemical Engineering Central South University Changsha 410083 China,Changde 415000 China College of Chemistry Xiangtan University Xiangtan 411105 China,Changde 415000 China,Changde 415000 China,Changde 415000 China,Changde 415000 China School of Chemistry and Chemical Engineering Central South University Changsha 410083 China,Changsha 410083 China,Changsha 410083 China
摘    要:Chromatography-mass spectrometry(GC-MS)was used to analyze the volatile components of cut tobacco samples with the help of heuristic evolving latent projections(HELP).After extracting with simultaneous distillation and extraction method,the volatile components in cut tobacco were detected by GC-MS.Then the obtained original two-dimensional data were resolved into pure mass spectra and chromatograms.The qualitative analysis was performed by similarity searches in the national institute of standards and technology(NIST)mass database with the obtained pure mass spectrum of each component and the quantitative results were obtained by calculating the volume of total two-way response.The accuracy of qualitative and quantitative results were greatly improved by using the two-dimensional comprehensive information of chromatograms and mass spectra.107 of 141 separated constituents in the total ion chromatogram of the volatile components were identified and quantified,accounting for about 88.01% of the total content.The result proves that the developed method is powerful for the analysis of complex cut tobacco samples.

关 键 词:化学计量学  气体色谱质量  光谱测量法  投射
收稿时间:24 December 2006
修稿时间:2006-12-24

Determination of volatile components in cut tobacco with gas chromatography-mass spectrometry and chemometric resolution
Huang Lan-fang , Wu Ming-jian , Sun Xian-jun , Zhong Ke-jun , Guo Zi-ming , Dai Yun-hui , Huang Ke-long and Guo Fang-qiu.Determination of volatile components in cut tobacco with gas chromatography-mass spectrometry and chemometric resolution[J].Journal of Central South University of Technology,2007,14(4):504-508.
Authors:Huang Lan-fang  Wu Ming-jian  Sun Xian-jun  Zhong Ke-jun  Guo Zi-ming  Dai Yun-hui  Huang Ke-long and Guo Fang-qiu
Affiliation:1. Technical Center of Changde Cigarette Factory, Changde 415000, China; 2. School of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China; 3.College of Chemistry, Xiangtan University, Xiangtan 411105, China
Abstract:Chromatography-mass spectrometry(GC-MS)was used to analyze the volatile components of cut tobacco samples with the help of heuristic evolving latent projections(HELP).After extracting with simultaneous distillation and extraction method,the volatile components in cut tobacco were detected by GC-MS.Then the obtained original two-dimensional data were resolved into pure mass spectra and chromatograms.The qualitative analysis was performed by similarity searches in the national institute of standards and technology(NIST)mass database with the obtained pure mass spectrum of each component and the quantitative results were obtained by calculating the volume of total two-way response.The accuracy of qualitative and quantitative results were greatly improved by using the two-dimensional comprehensive information of chromatograms and mass spectra.107 of 141 separated constituents in the total ion chromatogram of the volatile components were identified and quantified,accounting for about 88.01% of the total content.The result proves that the developed method is powerful for the analysis of complex cut tobacco samples.
Keywords:chemometrics  gas chromatography-mass spectrometry  heuristic evolving latent projection  cut tobacco  volatile component
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号