首页 | 官方网站   微博 | 高级检索  
     


A flow rate measurement method for horizontal oil-gas-water three-phase flows based on Venturi meter,blind tee,and gamma-ray attenuation
Abstract:Online horizontal oil-gas-water three-phase flow rate monitoring is essential for reliable operations during industrial production. A flow rate measurement method is developed in horizontal oil-gas-water three-phase flows by combining a blind tee, a Venturi meter, and a gamma-ray densitometer. The blind tee is installed at the test section entrance to homogenize the mixture by transforming the horizontal flow to a vertical upward flow. The Venturi meter is used for the total flow rate measurement. The dual-energy gamma-ray densitometer is used for phase holdup measurement. In the present method, blind-tee mixing effects and oil-water mixture slip behavior is essential, which were experimentally analyzed in this work. The phase inversion was found in the oil-water mixture with the increasing of the oil volume fraction. Besides, the addition of the gas reduces the oil-water slip ratio. For the range of 0–35% and 65–100% oil fraction in the oil-water liquid, the oil-water mixture can be well treated as a pseudo homogenous liquid with a slip ratio of 0.9–1.1. A three-phase flow rate model is then established for these conditions. The method was validated by horizontal oil-gas-water three-phase flows with average relative errors of 3.2% for the total flow rates, 4.3% for the gas flow rates, 11.5% for the oil flow rates, and 7.8% for the water flow rates.
Keywords:Three-phase flow  Flow rate model  Slip ratio  Blind tee  Dual-energy gamma densitometer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号