首页 | 官方网站   微博 | 高级检索  
     

某600MW超临界机组振动故障分析与处理
引用本文:黎瑜春,蔡强. 某600MW超临界机组振动故障分析与处理[J]. 电力技术, 2014, 0(3): 55-58
作者姓名:黎瑜春  蔡强
作者单位:国内福建省电力有限公司电力科学研究院,福建福州350007
摘    要:某电厂引进型600 MW超临界机组3号瓦轴振突然变大,幅值在80~240 μm波动,2号瓦瓦温升高到106℃,严重威胁机组的安全运行通过变油温、变负荷、变真空试验,采用正向推理方法,准确分析了振动故障原因并给出了处理措施,对大型机组类似振动故障分析具有借鉴意义.

关 键 词:超临界机组  振动  故障分析  故障处理

Analysis and Treatment on Vibration Fault of 600-MW Steam Turbines
LI Yu-chun,CAI Qiang. Analysis and Treatment on Vibration Fault of 600-MW Steam Turbines[J]. , 2014, 0(3): 55-58
Authors:LI Yu-chun  CAI Qiang
Affiliation:1.Fujian Electric Power Research Institute, Fuzhou 350007, China;)
Abstract:The shaft vibration of an imported 600-MW supercritical unit rises suddenly.The vibration amplitude of Bearing 3 fluctuates between 80 μm and 240 μm and the temperature of Bearing 2 rises to 106 ℃.The problem seriously threatens the security of unit operation.The reasons which cause the vibration fault are identified through a series of testing,such as variable oil-pressure test,variable load test and variable vacuum test.The corresponding treatment measures are also proposed.The experience should be helpful to handle the large units with similar issues.
Keywords:supercritical unit  vibration  fault analysis  fault treatment