首页 | 官方网站   微博 | 高级检索  
     

基于电子鼻与GC-MS分析精氨酸-葡萄糖美拉德反应体系挥发性风味成分的差异性
引用本文:贝翠平,柳艳霞,赵改名,张丽萍,张忆臻. 基于电子鼻与GC-MS分析精氨酸-葡萄糖美拉德反应体系挥发性风味成分的差异性[J]. 食品研究与开发, 2021, 42(6): 146-154
作者姓名:贝翠平  柳艳霞  赵改名  张丽萍  张忆臻
作者单位:河南农业大学食品科学技术学院;河南省肉制品加工与质量安全控制重点实验室
基金项目:国家自然科学基金项目(31701628)。
摘    要:为研究不同反应时间对精氨酸-葡萄糖美拉德反应体系挥发性风味物质的影响,利用电子鼻与气相色谱-质谱联用(gas chromatography-mass spectrometry,GC-MS),结合主成分分析(principal component analysis,PCA)和线性判别分析(linear discrimin...

关 键 词:美拉德  精氨酸  线性判别分析  主成分分析  电子鼻  气相色谱-质谱法
收稿时间:2020-10-15

Analysis of the Difference of Volatile Flavor Components of Arginine-Glucose Maillard Reaction System Based on Electronic Nose and GC-MS
BEI Cui-ping,LIU Yan-xi,ZHAO Gai-ming,ZHANG Li-ping,ZHANG Yi-zhen. Analysis of the Difference of Volatile Flavor Components of Arginine-Glucose Maillard Reaction System Based on Electronic Nose and GC-MS[J]. Food Research and Developent, 2021, 42(6): 146-154
Authors:BEI Cui-ping  LIU Yan-xi  ZHAO Gai-ming  ZHANG Li-ping  ZHANG Yi-zhen
Affiliation:(College of Food Science and Technology,Henan Agricultural University,Zhengzhou 450002,Henan,China;Henan Key Lab of Meat Processing and Quality Safety Control,Zhengzhou 450002,Henan,China)
Abstract:In order to study the effect of different reaction times on the volatile flavor compounds of the arginine-glucose Maillard reaction system,an electronic nose and gas chromatography-mass spectrometry(GC-MS)were used in conjunction with principal component analysis(PCA)and linear discriminant analysis(LDA)were used to analyze the difference of the volatile flavor components of the arginine-glucose Maillard reaction system at different reaction times.The results showed that both PCA and LDA could distinguish 30 d and 40 d samples better,but for other samples,PCA was better than LDA.GC-MS had detected a total of 50 volatile substances from the arginine-glucose Maillard reaction system,which could be divided into 6 types of substances including alcohols,aldehydes,ketones,esters,alkanes and other compounds.Ester substances were the main volatile substances in the 10 d and 20 d samples,and alcohols were the main volatile constituents in the 20 d and 30 d samples.The main volatile constituents were significantly different at different reaction times.Principal component analysis was performed on the volatile substances of different arginine-glucose Maillard reaction system samples,the quality evaluation model was established,and the order of comprehensive scores at different times was 20,10,60,40,30 d and 50 d.
Keywords:Maillard  arginine  linear discriminant analysis  principal component analysis  electronic nose  gas chromatography-mass spectrometry
本文献已被 维普 等数据库收录!
点击此处可从《食品研究与开发》浏览原始摘要信息
点击此处可从《食品研究与开发》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号