首页 | 官方网站   微博 | 高级检索  
     

全热交换器节能与经济效益分析实例
引用本文:邬守春 焦良珍. 全热交换器节能与经济效益分析实例[J]. 中国建设信息, 2004, 0(3): 22-25
作者姓名:邬守春 焦良珍
作者单位:[1]中国轻工业武汉设计院 [2]武汉科技大学
摘    要:武汉大学实验动物中心净化空调系统原设计为全新风系统.能量消耗巨大。笔者建议在此系统中配置热回收设备,被业主采纳。工程实施后.节省直接工程投资38.24万元.节省间接工程投资63.9万元.每年节约用电38.87万kWh,节约运行电费26.51万元.文测结果表明.回收的热量约为513.6MJ/h.

关 键 词:全热交换器 建筑节能 经济效益 框架结构 空调净化

Project Analysis on Energy Saving and Economic Benefit of Full-heat Exchanger
by Wu Shouchun Jiao Liangzhen China Light Industrial Wuhan Design Institute. Project Analysis on Energy Saving and Economic Benefit of Full-heat Exchanger[J]. Information of China Construction, 2004, 0(3): 22-25
Authors:by Wu Shouchun Jiao Liangzhen China Light Industrial Wuhan Design Institute
Affiliation:by Wu Shouchun* Jiao Liangzhen *China Light Industrial Wuhan Design Institute
Abstract:The cleaning air conditioning system of Wuhan University Animal Laboratorial Center, which was originally designed as full fresh air system, but the energy consumption of this system was huge. Thus the author introduces to set full-heat exchanger in the system, which has been adopted by the owner. After the project is put into use, and it has saved direct project cost for 382 400 RMB, indirect project cost for 639 000 RMB, electric power 388 700 kWh, which was approximately 265 100 RMB per year. The actual test shows 513.6MJ/h heat can be recycled.
Keywords:energy saving energy recycling initial investment operation cost