首页 | 官方网站   微博 | 高级检索  
     

微波消解光度法快速测定无挥发性废水的化学需氧量
引用本文:吴学深,夏东升,陆晓华,曾庆福.微波消解光度法快速测定无挥发性废水的化学需氧量[J].应用化工,2005,34(8):503-505.
作者姓名:吴学深  夏东升  陆晓华  曾庆福
作者单位:1. 武汉科技学院,环境科学研究所,湖北,武汉,430073;华中科技大学,环境科学与工程学院,湖北,武汉,430074
2. 武汉科技学院,环境科学研究所,湖北,武汉,430073
3. 华中科技大学,环境科学与工程学院,湖北,武汉,430074
基金项目:国家863基金资助项目(2002AA601300)
摘    要:介绍了一种微波消化制样、分光光度快速测定无挥发性废水化学需氧量的新方法,确定了微波功率250W,硫酸-硫酸银溶液10 mL,消解时间为10 m in为最佳消解条件,并于351 nm波长处分光光度测定过量Cr(Ⅵ)的浓度,结果表明,吸光度与COD值在0~400 mg/L范围内呈良好的线性关系,能有效排除C l-的干扰,实际水样测定结果的准确度达到99%,精密度小于4%,加标回收率达到98.7%。并与经典重铬酸钾回流法进行了对比,证实了两种方法处于同一种水平。

关 键 词:COD  微波消解  光度法
文章编号:1671-3206(2005)08-0503-03
修稿时间:2005年6月30日

Rapid photometric determination of COD in no-volatility in waste water with microwave heating sample digestion
WU Xue-shen,XIA Dong-sheng,LU Xiao-hua,ZENG Qing-fu.Rapid photometric determination of COD in no-volatility in waste water with microwave heating sample digestion[J].Applied chemical industry,2005,34(8):503-505.
Authors:WU Xue-shen  XIA Dong-sheng  LU Xiao-hua  ZENG Qing-fu
Affiliation:WU Xue-shen~
Abstract:This paper introduced a new spectrophotometric method for high-speed measurement of COD of no-volatility waste water by using microwave-heating.The optimal condition of digestion was obtained,which indicated that the power of microwave is 250 W,the volume of sulfuric acid and argentine sulfate is 10 mL and the time of digestion is 10 min.The surplus Cr(Ⅵ) was determined in 351 nm wavelength by spectrophotometric method and the results showed that values of absorbance and COD are in good linear relation when COD value is 0~400 mg/L,the interference of Cl~-can be removed efficiently,the accuracy is 99%,the precision of the method is less than 4%,and the recovery is 98.7%.The comparison between this method and conventional refluxing method was carried out and testified that two methods are on the same level.
Keywords:COD  microwave digestion  spectrophotometry
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号