首页 | 官方网站   微博 | 高级检索  
     

对比剂双流技术注射方案在头颈联合CTA检查中的初步应用
引用本文:胡广柱,陈峰,朱大荣,汪荣.对比剂双流技术注射方案在头颈联合CTA检查中的初步应用[J].影像科学与光化学,2021,39(1):40-43.
作者姓名:胡广柱  陈峰  朱大荣  汪荣
作者单位:浙江大学医学院附属第一医院放射科,浙江杭州310000;浙江大学医学院附属杭州市第一人民医院放射科,浙江杭州310000;浙江大学医学院附属第一医院放射科,浙江杭州310000;浙江大学医学院附属杭州市第一人民医院放射科,浙江杭州310000
摘    要:为探讨对比剂双流技术注射方案在双源CT头颈联合CTA检查中的应用价值,将在我院接受双源CT头颈联合CTA检查的164例病例,随机分成传统注射组和双流注射组.比较两组间对比剂用量、颈总动脉起始部、颈总动脉分叉部、颈内动脉虹吸部、Ml段感兴趣区的CT值,并对两组间颈总动脉、颈内外动脉和大脑中动脉综合显示情况及远端细小动脉分...

关 键 词:对比剂  双流注射技术  头颈联合CTA  双源CT

Preliminary Application of Contrast Agent Dual-flow Technology Injection Scheme in Combined Head and Neck CTA
HU Guangzhu,CHEN Feng,ZHU Darong,WANG Rong.Preliminary Application of Contrast Agent Dual-flow Technology Injection Scheme in Combined Head and Neck CTA[J].Imaging Science and Photochemistry,2021,39(1):40-43.
Authors:HU Guangzhu  CHEN Feng  ZHU Darong  WANG Rong
Affiliation:(Department of Radiology,The First Affiliated Hospital,Zhejiang University School of Medicine,Hangzhou 310000,Zhejiang,P.R.China;Department of Radiology,Affiliated Hangzhou First People’s Hospital,Zhejiang University School of Medicine,Hangzhou 310000,Zhejiang,P.R.China)
Abstract:In order to explore the application value of the contrast agent dual-flow technology injection scheme in combined head and neck CTA examination of dual-source CT,164 cases of combined head and neck CTA examination in our hospital were randomly divided into traditional injection group and dual-flow injection group.The volume of contrast agent,CT values of the origin of common carotid artery,bifurcation of common carotid artery,siphon part of internal carotid artery and M1 segment of interest area were compared between the two groups.Subjective quality score was evaluated for the comprehensive display of common carotid artery,internal and external carotid artery,middle cerebral artery and distal small artery branch between the two groups.The results showed that there was no statistically significant in CT value,subjective quality score of common carotid artery,internal and external carotid artery and middle cerebral artery between the two groups(P>0.05);the volume of contrast agent and the subjective quality score of distal small artery branch were statistically significant difference(P<0.05).From the above results,it can be seen that the contrast agent dual-flow technology injection scheme has good application value in combined head and neck CTA examination of dual-source CT.
Keywords:contrast agent  dual-flow technique  combined head and neck CTA  double-source CT
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23