首页 | 官方网站   微博 | 高级检索  
     

化妆品中维生素D2、维生素D3的高效液相色谱测定
引用本文:朱英,杨艳伟,王歆.化妆品中维生素D2、维生素D3的高效液相色谱测定[J].卫生研究,2005,34(5):624-625.
作者姓名:朱英  杨艳伟  王歆
作者单位:1. 中国疾病预防控制中心环境与健康相关产品安全所,北京,100021
2. 北京工业大学
基金项目:卫生部化妆品标准委员会标准研制项目
摘    要:目的建立化妆品中维生素D2、维生素D3的高效液相色谱检测方法,用于监测化妆品中维生素D2、维生素D3的使用情况.方法通过考察不同型号液相色谱柱、不同类型流动相及配比,确定了最佳色谱条件,并进行了线性范围、检出限、精密度、准确度试验.结果在Alltima C18(250mm×4.6mm I.D.,5μμm)色谱柱;流动相为甲醇乙腈=9010;流速为1.0 ml/min;检测波长为265nm;柱温为25℃时,维生素D2、维生素D3在0.5~100mg/L浓度范围内具有良好的线性关系,检出限分别为0.12mg/L和0.06mg/L;不同浓度维生素D2、维生素D3的变异系数分别小于3.8%和3.5%;加标量为20μg/g时,维生素D2、维生素D3的加标回收率分别在94.2%~101.4%和91.6%~97.2%之间.结论该方法具有操作简便、准确、快速等特点,适于同时测定化妆品中的维生素d2、维生素D3.

关 键 词:维生素D2  维生素D3  高效液相色谱  化妆品
文章编号:1000-8020(2005)05-0624-02
收稿时间:2004-12-07
修稿时间:2004年12月7日

Determination of vitamins D2, vitamin D3 in cosmetics by high performance liquid chromatography
Zhu Ying,Yang Yan-wei,Wang Xin.Determination of vitamins D2, vitamin D3 in cosmetics by high performance liquid chromatography[J].Journal of Hygiene Research,2005,34(5):624-625.
Authors:Zhu Ying  Yang Yan-wei  Wang Xin
Affiliation:Institute for Environmental Hygiene and Health Related Product Safety, Chinese Center for Disease Control and Prevention, Beijing, China.
Abstract:OBJECTIVE: A high performance liquid chromatography method was used to detect vitamins D2 and vitamin D3, which is useful to know the use of vitamins D2 and vitamin D3 in cosmetics, prohibit the influx of cosmetics containing vitamins D2 and vitamin D3 to cosmetic market, safeguard the health of consumers. METHODS: A high performance liquid chromatography method was established for determination of vitamins D2 and vitamin D3 in cosmetics. The separation condition was optimized by trying different type of columns and mobile phases. RESULTS: The experiment goes on a Alltima C18 column (250 mm x 4.6 mm I. D., 5 microm)using methanol-acetonitrile (90: 10) as mobile phase at a flow rate of 1.0 ml/min, with the column temperature 25 degrees C and detection wave 265nm. The liner range is from 0.5 mg/L to 100 mg/L with good relationship. The detection limit of vitamin D2 is 0. 12 mg/L, the precision is less than 3.8% and recovery varies from 94.2% to 101.4%, while the detection limit of vitamin D3 is 0.06 mg/L, the precision is less than 3.5% and recovery varies from 91.6% to 97.2%. CONCLUSION: The method is simple, precise and accurate, which is suitable for the determination of vitamins D2 and vitamin D3 in cosmetics.
Keywords:vitamin D2  vitamin D3  high performance liquid chromatography  cosmetics
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号