首页 | 官方网站   微博 | 高级检索  
     

计算机手术导航系统对股骨头表面假体植入精确度的研究
引用本文:侯明夫,王黎明,喻忠,桂鉴超,蒋纯志,姚京东,徐燕.计算机手术导航系统对股骨头表面假体植入精确度的研究[J].生物医学工程与临床,2008,12(1):50-52.
作者姓名:侯明夫  王黎明  喻忠  桂鉴超  蒋纯志  姚京东  徐燕
作者单位:南京医科大学,附属南京第一医院,骨科,江苏,南京,210006
摘    要:目的研究非影像手术导航系统对股骨头表面假体植入位置的影响。方法25例股骨头坏死患者(共32髋)。其中男性16例,女性9例,年龄(36±7)岁。随机分为2组,计算机导航手术组(导航组)11例(16髋),在导航系统下进行股骨头表面置换术,设定髋最佳植入柄颈角为0°,柄干角为140°;对照组14例(16髋)采用传统手术。术后测定假体植入的角度,进行手术评估。结果术后导航组植入股骨假体柄干角为(140.5±1.7)°,对照组为(135.9±6.5)°,导航组的股骨假体柄颈角为(O.30±1.40)°,对照组柄颈角为(-4.93±4.30)°,两组差异具有统计学意义(P〈0.05)。Harris评分,导航组优14髋,良2髋;对照组优9髋,良4髋,中3髋。导航组无一例发生肢体缩短、旋转、内外翻畸形,对照组2例发生短缩畸形,1例内翻15°畸形。随访(14±4)个月,均无假体松动、脱位。结论在非影像手术导航系统下手术操作可以精确地植入假体,减少假体松动的发生,具有重要的临床价值。

关 键 词:髋关节  表面置换术  导航
文章编号:1009-7090(2008)01-0050-03
收稿时间:2007-07-23
修稿时间:2007-09-10

Study on implantation accuracy of femoral head surface prostheses placement with computer navigated surgery
HOU Ming-fu,WANG Li-ming,YU Zhong,GUI Jian-chao,JIANG Chun-zhi,YAO Jing-dong,XU Yan.Study on implantation accuracy of femoral head surface prostheses placement with computer navigated surgery[J].Biomedical Engineering and Clinical Medicine,2008,12(1):50-52.
Authors:HOU Ming-fu  WANG Li-ming  YU Zhong  GUI Jian-chao  JIANG Chun-zhi  YAO Jing-dong  XU Yan
Affiliation:(Department of Orthopedic, The Nanjing First Hospital Affiliated to Nanjing Medical Universty,Nartjing 210006,Jiangsu, China)
Abstract:Objective To study the accuracy of femoral head surface component placement by non-imaging assisted surgery. Methods A total of 25 patients with femoral head osteonecrosis (32 hips ), male 16 and female 9 with mean age (36 ± 7) years, were randomly divided into 2 groups. In computer navigated surgery group 11 patients ( 16 hips) with femoral head osteonecrosis were operated with non-imaging computer navigated surgery. According to the design of the study ,the femoral component was placed in best stem-graft angle of 140° and stem-neck angle of 0°. The control group enrolled 14 patients ( 16 hips ) operated with conventional mechanically guided procedure. Postoperative component position was measured. Results In the computer navigated surgery group, stem-graft angle achieved (140.5 ± 1.7 )° and stem-neck angle achieved (0.3 ±1.4)°. In the control group, stem-graft angle were (135.9 ± 6.5 )° and stem-neck angle were (-4.93 ± 4.30)°. The difference of stem femoral angle was demonstrated statistically significant (P 〈 0.05). Conclusion The femoral head surface prostheses can be in planted accurately by non-imaging computer navigated surgery. It can reduce prostheses flexible with important clinical value.
Keywords:hip  surface replacement  navigation
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23