Arthroscopic treatment of type III tibial spine fractures using absorbable fixation |
| |
Authors: | Shepley Robert W |
| |
Affiliation: | The Orthopaedic & Fracture Clinic, PA, Northfield, MN 55057, USA. |
| |
Abstract: | Over 2 years, five patients (average age 15 years) were diagnosed with a type III tibial spine fracture. All five fractures were treated with arthroscopic reduction and internal stabilization using absorbable fixation. At average 8.5-year follow-up, patients were interviewed and examined. Results were documented regarding function, KT-1000 testing, range of motion, and radiographic findings. All five patients reported no functional limitations despite participation in high-demand sports. Stability testing by KT-1000 revealed no objective instability. Range of motion was normal when the knee was immobilized in full extension postoperatively. No radiographic abnormality was noted at follow-up. |
| |