首页 | 官方网站   微博 | 高级检索  
     


Long-path FTIR Measurements of Volatile Organic Compounds in an Industrial Setting
Authors:George M. Russwurm  Robert H. Kagann  Orman A. Simpson  William A. McClenny  William F. Herget
Affiliation:1. NSI Technology Services Corporation, Research Triangle Park , North Carolina , USA;2. MDA Scientific, Inc. , Norcross , Georgia , USA;3. U.S. Environmental Protection Agency, Research Triangle Park , North Carolina , USA;4. Nicolet , Madison , Wisconsin , USA
Abstract:A long-path Fourier transform spectrometer was used to make measurements of volatile organic compounds in an industrial complex in New Castle, Delaware as part of the Superfund Innovative Technology Evaluation (SITE) program. These data are compared to data taken with a whole-air canister technique. To provide an effective comparison the canisters were transported along the path for a 32-min period. For each FTIR spectrum, 256 interferograms were co-added over a 4-mln period. Eight individual spectra were then co-added to obtain the comparison data.