首页 | 官方网站   微博 | 高级检索  
     

仿真人体体模在全身照射中剂量评估及监测的研究
引用本文:周一兵,杨勇. 仿真人体体模在全身照射中剂量评估及监测的研究[J]. 中国医疗器械杂志, 2001, 25(6): 342-344,351
作者姓名:周一兵  杨勇
作者单位:第三军医大学新桥医院全军肿瘤中心,
摘    要:利用仿真人体体模和热释光测量设备,在X射线全身照射治疗条件下,测量了人体各重要组织和器官的吸收剂量,获得了人体内剂量分布信息,对全身放射治疗中人体各组织和器官的实际受照剂量进行评估和监测。

关 键 词:仿真人体体模 全身照射 均匀性 剂量测量
文章编号:1000-6974(2001)06-0342-03

Study on Radiation Dose Estimation and Monitor in TBI Usi ng an Anthropomorphic Phantom
ZHOU Yi bing,YANG Yong Xingiao Hospital,the Third Military Medical University,Changqing. Study on Radiation Dose Estimation and Monitor in TBI Usi ng an Anthropomorphic Phantom[J]. Chinese journal of medical instrumentation, 2001, 25(6): 342-344,351
Authors:ZHOU Yi bing  YANG Yong Xingiao Hospital  the Third Military Medical University  Changqing
Affiliation:Xingiao Hospital, Third Military Medical University, Changqing.
Abstract:Absorbed doses and the dose distributions at important tissues and organs in an anthropomorphic phantom are measured using TLD under the TBI conditions. The dose for each tissue or organ is also estimated and monitored for TBI treatment.
Keywords:anthropomorphic phantom   TBI   uniformity   radiation dose measurement  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23