首页 | 官方网站   微博 | 高级检索  
     

配电网电能质量测试系统的设计与仿真
引用本文:田庆生,刘二勇,梁仕斌,许伯强,陈柯豪,丁心志. 配电网电能质量测试系统的设计与仿真[J]. 电力系统保护与控制, 2017, 45(11): 115-120
作者姓名:田庆生  刘二勇  梁仕斌  许伯强  陈柯豪  丁心志
作者单位:云南电力试验研究院集团有限公司,云南 昆明 650217,云南电网公司研究生工作站,云南 昆明 650217 ;华北电力大学电气工程学院,河北 保定 071003,云南电力试验研究院集团有限公司,云南 昆明 650217,华北电力大学电气工程学院,河北 保定 071003,云南电网公司昆明供电局,云南 昆明 650011,云南电力试验研究院集团有限公司,云南 昆明 650217
基金项目:国家自然科学基金项目(51177077);云南电网公司科技项目(YNKJ00000053)
摘    要:针对目前几种电能质量干扰发生装置的模型存在的不足之处,提出了一种基于电力电子技术的电能质量干扰源设计方案。采用DSP控制器、三相PWM有源可控整流和可控逆变控制技术,结合不对称与高谐波条件下的MRF补偿算法,以15 kVA 容量为例对加入干扰源的配电网动模系统进行了仿真分析。仿真结果表明,加入干扰源的动模系统可以模拟多种电能质量干扰环境,并且可用于大功率场合,运行经济,效益较好,较好地满足了对电能质量控制治理设备测试的有效性和实用性要求。

关 键 词:电能质量;动模系统;干扰源;DSP
收稿时间:2016-06-03
修稿时间:2016-10-14

Design and simulation of power quality testing system for distribution network
TIAN Qingsheng,LIU Eryong,LIANG Shibin,XU Boqiang,CHEN Kehao and DING Xinzhi. Design and simulation of power quality testing system for distribution network[J]. Power System Protection and Control, 2017, 45(11): 115-120
Authors:TIAN Qingsheng  LIU Eryong  LIANG Shibin  XU Boqiang  CHEN Kehao  DING Xinzhi
Affiliation:Yunnan Electric Test & Research Institute Group, Kunming 650217, China,Graduate Student Workstation of Yunnan Power Grid Corporation, Kunming 650217, China;School of Electrical Engineering, North China Electric Power University, Baoding 071003, China,Yunnan Electric Test & Research Institute Group, Kunming 650217, China,School of Electrical Engineering, North China Electric Power University, Baoding 071003, China,Kunming Electric Power Supply Bureau, Kunming 650011, China and Yunnan Electric Test & Research Institute Group, Kunming 650217, China
Abstract:Based on the existing shortcomings of current model of several kinds of power quality disturbance device, a scheme of power quality disturbance source based on power electronic technology is proposed. Using DSP controller, active three-phase PWM rectifier and controllable inverter control methods, combining MRF compensation algorithm under the condition of asymmetry and high frequency, and taking the 15 kVA capacity as an example, the dynamic simulation system of power distribution network after adding disturbance source is simulated and analyzed. Simulation results show that the dynamic simulation system with interference source can simulate lots of kinds of power quality disturbance environment, which can be used in high power applications. And the operation is economical and better efficient, and can meet the effectiveness and practicality requirements on the test of the power quality control equipment. This work is supported by National Natural Science Foundation of China (No. 51177077) and Science and Technology Project of Yunan Power Grid (No. YNKJ00000053).
Keywords:power quality   dynamic simulation system   disturbance source   DSP