摘    要:在不同条件下 ,对 1 2MW循环流化床锅炉 (CFB)燃烧室内硫化物的浓度进行测量 ,数据显示 :大部分硫在密相床层予以释放 ,在加有石灰石的情况下 ,二次风入口处可测得高浓度SO2 ,在增强的空气分级传送情况下 ,大约有 3 0 0ppm的硫化物可测得。

关 键 词:SO2  浓度  测试  流化床锅炉
文章编号:CN31-1508(2002)05-0016-04
修稿时间:2001-08-04

Measurements of Sulfur compounds inside the Combustion chamber of a CFB
LIU Jia-ming. Measurements of Sulfur compounds inside the Combustion chamber of a CFB[J]. Boiler Technology, 2002, 33(5): 16-19
Authors:LIU Jia-ming
Affiliation:LIU Jia ming
Abstract:The concentration of sulfur compounds the combustion of a 12MW circulating fluidized-bed boiler was measured at different conditions. The date obtained showed that most of the sulfur is released in the dense bed. In presence of limestone, a high concentration of SO 2 was seen below the secondary air inlet. Under the condition of intensified air-staging, 300ppm SO 2 was found.