首页 | 官方网站   微博 | 高级检索  
     

Application of Single—labelled Probe—primer in PCR Amplification to the Detection of Hepatitis B Virus DNA
作者姓名:KONG  De-Ming SHEN  Han-Xi
作者单位:ChemicalSchool,NankaiUniversity,Tianjin300071,China
基金项目:ProjectsupportedbytheNationalNaturalScienceFoundationofChina (No .2 0 0 75 0 12 )
摘    要:A new method based on the incorporation of a single-lablled probe-primer into polymerase chain reaction(PCR) for the detection of PCR-amplified DNA in a closed system is reported.The probeprimerc consists of a specific probe sequence on the 5‘‘‘‘‘‘‘‘-end and a primer sequence on the 3‘‘‘‘‘‘‘‘-end.A flurophore is located at the 5‘‘‘‘‘‘‘‘end.The primeR-quencher is an oligonucleotide,which is complementary to the probe sequence of probe-primer and labelled with a quencher at the 3‘‘‘‘‘‘‘‘-end.In the duplex formed by probe-primer and primer-quencher.the fluorophore and quencher are kept in close proximity to each other.Therefore the fluorescence is quenched.During PCR amplificatio,the specific probe sequence of probeprimer binds to its complement within the same strand of DNA,and is cleaved by Taq DNA polymerase,resulting in the restoration of fluorescence.This system has the same energy transfer mechanism as molecular beacons,and a good quenching effciency can be ensured.Following optimization of PCR conditions,this method was used to detect hepatitis b virus(HBV) dna in patient sera.This technology eliminates the risk of carry-over contamination,simplifies the amplification assay and opens up new possibilities for the real-time detection of the amplified DNA.

关 键 词:PCR  DNA  聚合物链式反应  HBV  乙型肝炎病毒  检测

Application of Single-labelled Probe-primer in PCR Amplification to the Detection of Hepatitis B Virus DNA
KONG,De-Ming SHEN,Han-Xi.Application of Single-labelled Probe-primer in PCR Amplification to the Detection of Hepatitis B Virus DNA[J].Chinese Journal of Chemistry,2003,21(5):556-561.
Authors:Kong De‐Ming  Shen Han‐Xi
Abstract:A new method based on the incorporation of a single‐labelled probeprimer into polymerase chain reaction (PCR) for the detection of PCR‐amplified DNA in a closed system is reported. The probeprimer consists of a specific probe sequence on the 5′ ‐end and a primer sequence on the 3′‐end. A fluorophore is located at the 5′‐end. The primer‐quencher is an oligonucleotide, which is complementary to the probe sequence of probe‐primer and labelled with a quencher at the 3′‐end. In the duplex formed by probe‐primer and primer‐quencher, the fluorophore and quencher are kept in close proximity to each other. Therefore the fluorescence is quenched. During PCR amplification, the specific probe sequence of probe‐primer binds to its complement within the same strand of DNA, and is cleaved by Taq DNA polymerase, resulting in the restoration of fluorescence. This system has the same energy transfer mechanism as molecular beacons, and a good quenching efficiency can be ensured. Following optimization of PCR conditions, this method was used to detect hepatitis B virus (HBV) DNA in patient sera. This technology eliminates the risk of carry‐over contamination, simplifies the amplification assay and opens up new possibilities for the real‐time detection of the amplified DNA.
Keywords:probe  primer  polymerase chain reaction (PCR)  hepatitis B virus (HBV) DNA
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号