Assessment of cardiac function and synchronicity in subjects with isolated bundle branch block using Doppler imaging |
| |
Authors: | Niu Hong-xia Hua Wei Zhang Shu Sun Xin Wang Fang-zheng Chen Ke-ping Wang Hao Chen Xin |
| |
Affiliation: | 1. Centre of Arrhythmia Diagnosis and Treatment, Fuwai Hospital and Cardiovascular Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China 2. Department of Echocardiography, Fuwai Hospital and Cardiovascular Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China |
| |
Abstract: | Background Using tissue Doppler imaging and conventional echocardiographic technique, we examined the cardiac function and synchronicity in individuals with isolated right bundle branch block (RBBB) or left bundle branch block (LBBB) and assessed the relationship between QRS duration and synchronicity. Methods Subjects with isolated RBBB (n=20), LBBB (n=10) and normal controls (n=20) were studied with conventional echocardiography and tissue Doppler imaging. The difference between aortic and pulmonary preejection intervals was defined as interventricular delay. Parameters in septum and lateral wall were measured using tissue Doppler imaging, including peak sustained systolic velocity (S(M)), peak early (E(M)) and late (A(M)) diastolic velocities as well as time to peak velocities (T(S), T(E) and T(A)). Results Subjects with LBBB had lower S(M) and longer T(S) than did the RBBB and control groups (P<0.05, P<0.001 respectively). A significant difference was observed in E(M), being the lowest in the LBBB and the highest in the control group (P<0.05). Moreover, T(E) was longer in the LBBB group compared with the other two groups (P<0.001). Both A(M) and T(A) were similar among three groups (P>0.05). In the bundle branch block groups, one ventricle lagged about 40 ms behind the other. A significant correlation was found between interventricular delay and QRS duration (r =0.713, P<0.001).Conclusions Cardiac ventricles were not well synchronized with one ventricle lagging about 40 ms behind the other in subjects with LBBB or RBBB, even though only LBBB group showed barely perceptible, impaired cardiac function. In addition, QRS duration and cardiac asynchronicity were positively correlated. |
| |
Keywords: | bundle branch block synchronicity cardiac function tissue Doppler imaging |
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录! |
| 点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息 |
|
点击此处可从《中华医学杂志(英文版)》下载全文 |
|