首页 | 官方网站   微博 | 高级检索  
     

Gene Transfection Mediated by Ultrasound and Pluronic P85 in HepG2 Cells
作者姓名:王芬  李开艳  陈云超  邓远  洪恺
作者单位:Department of Medical Ultrasound Tongji Hospital Tongji Medical College Huazhong University of Science and Technology,Department of Medical Ultrasound Tongji Hospital Tongji Medical College Huazhong University of Science and Technology,Department of Medical Ultrasound Tongji Hospital Tongji Medical College Huazhong University of Science and Technology,Department of Medical Ultrasound Tongji Hospital Tongji Medical College Huazhong University of Science and Technology,Department of Medical Ultrasound Tongji Hospital Tongji Medical College Huazhong University of Science and Technology,Wuhan 430030 China,Wuhan 430030 China,Wuhan 430030 China,Wuhan 430030 China,Wuhan 430030 China
摘    要:In order to assess whether gene transfection could be mediated by ultrasound in associa- tion with P85 and find the appropriate parameters of ultrasound irradiation, the effects of ultrasound with or without P85 on gene transfection of HepG2 cells were examined. The HepG2 cells were irra- diated by ultrasound at 1 MHz, 0.4-2.0 W/cm2 and 50% duty cycle with plasmid encoding enhanced green fluorescent protein (EGFP) as a report gene. Forty-eight h later, the expression of EGFP was detected under the fluorescence microscopy. Transfection efficacy was quantitatively assessed by flow cytometry, and cell viability was evaluated by trypan blue exclusion. The results showed that the transfection efficacy was increased with the increases in ultrasound output power and the ideal trans- fection efficacy was achieved in HepG2 cells irradiated by ultrasound at 0.8 W/cm2 for 30 s. The transfection efficacy in ulstrasound P85 group was three times higher than in single ultrasound group (17.63±1.07)% vs (5.57±0.56)%, P<0.05]. The cell viability was about 81% and 62% in ultrasound group and ultrasound P85 group respectively. It was concluded that ultrasound in combination with P85 could mediate the gene transfection of HepG2 cells, ideal transfection efficacy was achieved by ultrasound irradiation at 0.8 W/cm2 for 30 s, and P85 could somewhat increase the damage to cells caused by ultrasound.

关 键 词:基因转染  超声波  聚醚  HepG2细胞
收稿时间:2007-10-20

Gene transfection mediated by ultrasound and Pluronic P85 in HepG2 cells
Fen Wang,Kaiyan Li,Yunchao Chen,Yuan Deng,Kai Hong.Gene Transfection Mediated by Ultrasound and Pluronic P85 in HepG2 Cells[J].Journal of Zuazhong University of Science and Technology: Medical Edition,2007,27(6):700-702.
Authors:Fen Wang  Kaiyan Li  Yunchao Chen  Yuan Deng  Kai Hong
Affiliation:Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
Abstract:In order to assess whether gene transfection could be mediated by ultrasound in association with P85 and find the appropriate parameters of ultrasound irradiation, the effects of ultrasound with or without P85 on gene transfection of HepG2 cells were examined. The HepG2 cells were irradiated by ultrasound at 1 MHz, 0.4-2.0 W/cm(2) and 50% duty cycle with plasmid encoding enhanced green fluorescent protein (EGFP) as a report gene. Forty-eight h later, the expression of EGFP was detected under the fluorescence microscopy. Transfection efficacy was quantitatively assessed by flow cytometry, and cell viability was evaluated by trypan blue exclusion. The results showed that the transfection efficacy was increased with the increases in ultrasound output power and the ideal transfection efficacy was achieved in HepG2 cells irradiated by ultrasound at 0.8 W/cm(2) for 30 s. The transfection efficacy in ulstrasound+P85 group was three times higher than in single ultrasound group (17.63+/-1.07)% vs (5.57+/-0.56)%, P<0.05]. The cell viability was about 81% and 62% in ultrasound group and ultrasound+P85 group respectively. It was concluded that ultrasound in combination with P85 could mediate the gene transfection of HepG2 cells, ideal transfection efficacy was achieved by ultrasound irradiation at 0.8 W/cm(2) for 30 s, and P85 could somewhat increase the damage to cells caused by ultrasound.
Keywords:ultrasound  P85  gene transfection  HepG2
本文献已被 CNKI 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号