首页 | 官方网站   微博 | 高级检索  
     

320排CT诊断头颈部副神经节瘤
引用本文:肖泽彬,曹代荣,江飞,游瑞雄,余帅. 320排CT诊断头颈部副神经节瘤[J]. 中国医学影像技术, 2014, 30(11): 1641-1644
作者姓名:肖泽彬  曹代荣  江飞  游瑞雄  余帅
作者单位:福建医科大学附属第一医院影像科, 福建 福州 350005;福建医科大学附属第一医院影像科, 福建 福州 350005;福建医科大学附属第一医院影像科, 福建 福州 350005;福建医科大学附属第一医院影像科, 福建 福州 350005;福建医科大学附属第一医院影像科, 福建 福州 350005
摘    要:目的 探讨320排CTA在头颈部副神经节瘤诊治中的应用价值。方法 对头颈部副神经节瘤21例患者行320排CTA检查, 并由2名具有10年以上工作经验的高级职称医师分析其影像资料。结果 21例共30个副神经节瘤, 其中颈动脉体瘤20个, 颈静脉球瘤9个, 迷走神经副节瘤1个;CT均表现为实性肿块、血供丰富和明显强化。VR、MIP及MPR可清晰显示病灶与周围组织的关系。所有副神经节瘤均进行术前分型, 结果与术后分型完全相同, 准确率达100%。结论 320排CTA可作为诊断头颈部副神经节瘤安全、准确的首选影像学检查方式。

关 键 词:副神经节瘤  头颈部肿瘤  体层摄影术,X线计算机  血管造影术
收稿时间:2014-06-07
修稿时间:2014-07-15

320-detector row CT in diagnosis of paraganglioma of head and neck
XIAO Ze-bin,CAO Dai-rong,JIANG Fei,YOU Rui-xiong and YU Shuai. 320-detector row CT in diagnosis of paraganglioma of head and neck[J]. Chinese Journal of Medical Imaging Technology, 2014, 30(11): 1641-1644
Authors:XIAO Ze-bin  CAO Dai-rong  JIANG Fei  YOU Rui-xiong  YU Shuai
Affiliation:Department of Radiology, the First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, China;Department of Radiology, the First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, China;Department of Radiology, the First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, China;Department of Radiology, the First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, China;Department of Radiology, the First Affiliated Hospital of Fujian Medical University, Fuzhou 350005, China
Abstract:Objective To evaluate the clinical value of 320-detector row CTA in diagnosis of paragangliomas of head and neck. Methods Totally 21 patients with paragangliomas in head and neck were examined by 320-detector row CTA, and their images were retrospectively reviewed by two experienced radiologists. Results There were 30 paragangliomas in the 21 patients, of which 20 were carotid body, 9 were glomus jugular, and 1 was vagal paragangliomas. All lesions were hypervascular solid tumors with intense enhancement. VR, MPR and MIP demonstrated clear images for the relation between tumors and the surrounding tissue. All tumors were classified before operation, which results were the same as post-operation pathology, the accuracy rate was 100%. Conclusion 320-detector row CTA can be a safe, accurate and preferred examination for paragangliomas.
Keywords:Paragangliomas  Head and neck neoplasms  Tomography, X-ray computed  Angiography
点击此处可从《中国医学影像技术》浏览原始摘要信息