不同辐照模式聚焦超声诱导人胰腺癌细胞凋亡的量效关系
引用本文:郭倩,姜立新,胡兵. 不同辐照模式聚焦超声诱导人胰腺癌细胞凋亡的量效关系[J]. 中国医学影像技术, 2011, 27(3): 479-482
作者姓名:郭倩  姜立新  胡兵
作者单位:上海交通大学附属第六人民医院超声医学科,上海超声医学研究所,上海,200233
摘    要: 目的 探讨不同辐照模式聚焦超声诱导人胰腺癌细胞凋亡的最佳辐照方案。方法 对人胰腺癌细胞系PaTu 8988t细胞悬液进行聚焦超声辐照:第1组为空白对照组,第2、3组采用脉冲辐照模式,第4、5组采用连续辐照模式,各组辐照剂量通过改变辐照时间来改变。以流式细胞仪检测辐照后24 h肿瘤细胞凋亡率及细胞死亡率。结果 超声辐照后各组的细胞悬液最高温度分别为28.00℃、(42.20±2.17)℃、(50.80±0.84)℃、(55.80±2.17)℃、(65.20±3.11)℃,各组间差异均有统计学意义(P均<0.05)。各辐照组的细胞凋亡率为(0.56±0.15)%、(1.28±0.16)%、(1.84±0.29)%、(5.74±1.15)%、(2.00±0.84)%,细胞死亡率为(3.28±0.59)%、(4.60±0.47)%、(8.64±2.69)%、(41.12±15.91)%、(49.70±8.02)%,各组间差异均有统计学意义(P均<0.05)。结论 聚焦超声辐照剂量在接近热凝固温度阈值时,采用连续辐照模式可获得较高的细胞凋亡率及细胞死亡率。

关 键 词:高强度聚焦超声消融  细胞凋亡  胰腺肿瘤  辐照模式
收稿时间:2010-09-14
修稿时间:2010-11-15

Dose-effect of human pancreatic carcinoma cell apoptosis induced by focused ultrasound with different radiation patterns
GUO Qian,JIANG Li-xin and HU Bing. Dose-effect of human pancreatic carcinoma cell apoptosis induced by focused ultrasound with different radiation patterns[J]. Chinese Journal of Medical Imaging Technology, 2011, 27(3): 479-482
Authors:GUO Qian  JIANG Li-xin  HU Bing
Affiliation:Department of Ultrasound in Medicine, the Sixth People's Hospital Affiliated to Shanghai Jiao Tong University, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, China;Department of Ultrasound in Medicine, the Sixth People's Hospital Affiliated to Shanghai Jiao Tong University, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, China;Department of Ultrasound in Medicine, the Sixth People's Hospital Affiliated to Shanghai Jiao Tong University, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, China
Abstract:Objective To explore the optimal radiation pattern of focused ultrasound induced pancreatic carcionoma cell apoptosis.Methods The human pancreatic carcinoma cell line PaTu 8988t suspension was radiated by focused ultrasound using 5 dose groups with different radiation time parameters and patterns.Pulsed radiation pattern was used in groups 2 and 3,while continuous radiation pattern was used in group 4 and 5,group 1 was taken as the controls.The ratio of focused ultrasound induced cell apoptosis and cell dea...
Keywords:High-intensity focused ultrasound ablation  Apoptosis  Pancreatic neoplasms  Radiation pattern