首页 | 官方网站   微博 | 高级检索  
     


Influence of KTP length on the performance intracavity frequencydoubled diode-pumped Nd:YVO4 lasers
Authors:Chen  YF
Affiliation:Precision Instrum. Dev. Center, Nat. Sci. Council, Hsinchu;
Abstract:We demonstrate an experimental study of the influence of potassium titanyl phosphate (KTP) length on the performance of intracavity frequency-doubled diode-pumped Nd:YVO4 lasers operating in continuous-wave (CW) mode and passive Q-switch mode. Theoretical and experimental results show that the optimum KTP length for CW mode is determined by the nonlinear coupling and walkoff effect and the highest optical conversion efficiency in CW mode is nearly 30% with a 10-mm KTP. On the other hand, a 2-mm KTP crystal, which is sufficient for efficient internal second-harmonic generation in a passive Q-switch mode, yield the highest peak green power of 240-W
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23