首页 | 官方网站   微博 | 高级检索  
     


Dynamic versus static respiratory mechanics in acute lung injury and acute respiratory distress syndrome
Authors:Stahl Claudius A  Möller Knut  Schumann Stefan  Kuhlen Ralf  Sydow Michael  Putensen Christian  Guttmann Josef
Affiliation:Department of Anesthesiology and Critical Care Medicine, Albert-Ludwigs-University, Freiburg, Germany.
Abstract:OBJECTIVES: It is not clear whether the mechanical properties of the respiratory system assessed under the dynamic condition of mechanical ventilation are equivalent to those assessed under static conditions. We hypothesized that the analyses of dynamic and static respiratory mechanics provide different information in acute respiratory failure. DESIGN: Prospective multiple-center study. SETTING: Intensive care units of eight German university hospitals. PATIENTS: A total of 28 patients with acute lung injury and acute respiratory distress syndrome. INTERVENTIONS: None. MEASUREMENTS: Dynamic respiratory mechanics were determined during ongoing mechanical ventilation with an incremental positive end-expiratory pressure (PEEP) protocol with PEEP steps of 2 cm H2O every ten breaths. Static respiratory mechanics were determined using a low-flow inflation. MAIN RESULTS: The dynamic compliance was lower than the static compliance. The difference between dynamic and static compliance was dependent on alveolar pressure. At an alveolar pressure of 25 cm H2O, dynamic compliance was 29.8 (17.1) mL/cm H2O and static compliance was 59.6 (39.8) mL/cm H2O (median interquartile range], p < .05). End-inspiratory volumes during the incremental PEEP trial coincided with the static pressure-volume curve, whereas end-expiratory volumes significantly exceeded the static pressure-volume curve. The differences could be attributed to PEEP-related recruitment, accounting for 40.8% (10.3%) of the total volume gain of 1964 (1449) mL during the incremental PEEP trial. Recruited volume per PEEP step increased from 6.4 (46) mL at zero end-expiratory pressure to 145 (91) mL at a PEEP of 20 cm H2O (p < .001). Dynamic compliance decreased at low alveolar pressure while recruitment simultaneously increased. Static mechanics did not allow this differentiation. The decrease in static compliance occurred at higher alveolar pressures compared with the dynamic analysis. CONCLUSIONS: Exploiting dynamic respiratory mechanics during incremental PEEP, both compliance and recruitment can be assessed simultaneously. Based on these findings, application of dynamic respiratory mechanics as a diagnostic tool in ventilated patients should be more appropriate than using static pressure-volume curves.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号