首页 | 官方网站   微博 | 高级检索  
     

中隔墙过热器管开裂分析与测试
引用本文:黄瑾,蔡传荣.中隔墙过热器管开裂分析与测试[J].福建分析测试,2000(1).
作者姓名:黄瑾  蔡传荣
作者单位:华能福州电厂,福州大学 福州 350200,福州 350002
摘    要:中隔墙过热器管在运行168小时后开裂,用光学和扫瞄电子显微镜分析和测试表明与设计和材质有关,本文还提出防范措施

关 键 词:中隔墙过热器管  开裂  分析与测试

The Rupture Analysis on the Cage Division Wall Overheat Tube
Huang Jing.The Rupture Analysis on the Cage Division Wall Overheat Tube[J].Fujian Anal Ysis & Testing,2000(1).
Authors:Huang Jing
Abstract:The cage division wall overheat tube suddenly ruptured only for 168 hour use. The causes of the ruptured were analyzed by means of optical microscope and scanning electron microscope. It is concluded that inproper configuration of the tube and insufficient strength of the tube material are main causes and the precaution measures also suggested.
Keywords:cage division wall overheat tube  rupture  analysis and testing