Internal-corrosion inhibitors for pipelines carrying deaerated heating water |
| |
Authors: | Yu V Balaban-Irmenin N G Fokina |
| |
Affiliation: | (1) JSC “Vserossiiskii Teplotekhnicheskii Institut” (VTI), Moscow, Russia |
| |
Abstract: | The effect of internal-corrosion inhibitors on heating-system pipelines is investigated. Tests were conducted on a testing
device for polarization measurements under conditions corresponding to the Rostov Heat-Supply System. The concentration of
OEDP-zinc, which provides a high degree of protection from general corrosion, is determined. The reagent has been successfully
incorporated into the Rostov No. 2 TPP.
__________
Translated from élektricheskie Stantsii, No. 7, July 2007, pp. 37–43. |
| |
Keywords: | heat-supply systems internal corrosion corrosion aggressiveness of water corrosion inhibitors corrosion rate of indicators adsorption |
本文献已被 SpringerLink 等数据库收录! |